Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures:

Pay attention to self-protection.

Remove victims from hazardous area.

Immediately remove soiled or soaked clothing and remove it to a safe distance. Keep victim warm, in a stabilized position and covered.

Do not leave victims unattended.

If the casualty is unconscious: Place the victim in the recovery position.

Inhalation:

Inhalation is possible if aerosols, mists, dusts, or smoke form.

Move victims into fresh air.

With labored breathing: Provide with oxygen. Consult a doctor.

If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.

Skin contact:

Wash off affected area immediately with plenty of water for at least 15 minutes.

If symptoms persist, consult a physician for treatment.

Eye contact:

With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.

In case of persistent discomfort: Consult an ophthalmologist.

Ingestion:

Rinse mouth.

Immediately give large quantities of water to drink.

Obtain medical attention.

Most important symptoms and effects, both acute and delayed:

Symptoms: None known.

Hazards: Other dangerous properties can not be excluded.

Indication of any immediate medical attention and special treatment needed:

This substance does not have any noteworthy noxious potential. Damage to health is thus not expected.

Fire-fighting measures

Extinguishing media:

Suitable extinguishing media:

All extinguishing substances suitable.

Unsuitable extinguishing media:

Do not use a solid water stream as it may scatter and spread fire.

Special hazards arising from the substance or mixture:

May be released in case of fire: carbon monoxide, carbon dioxide and nitrous gases.

Under certain fire conditions, traces of other toxic products may occur.

Advice for firefighters:

Water used to extinguish fire should not enter drainage systems, soil or stretches of water.

Contaminated extinguishing water must be treated at a suitable disposal plant in accordance with waste management laws.

In case of fire, remove the endangered containers and bring to a safe place, if this can be done safely.

Fire residues should be disposed of in accordance with the regulations.

Use water spray to cool unopened containers.

Keep out unprotected persons.

In case of fire: full protective suit and wear a self contained respiratory apparatus.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Keep unauthorized persons away.

Environmental precautions:

Observe regulations on prevention of water pollution (check, dam up, cover up).

Do not allow entrance in sewage water, soil, stretches of water, drainage systems, surface water.

If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up:

Pick up mechanically with a suitable material and collect in a suitable container.

Pack and label wastes like the pure substance.

Do not detach label from the delivery containers prior to disposal.

Disposal according to local authority regulations.

Reference to other sections:

Wear personal protective equipment; see section "Exposure controls / personal protection".

Handling and storage

Precautions for safe handling:

Use permissible in closed systems only.

Handle and transfer product in closed systems only (gas displacement device).

Ensure that apparatus and pipelines are free from leaks.

Do not ventilate into the open.

Suitable loading and unloading device required.

Conditions for safe storage, including any incompatibilities:

Advice on protection against fire and explosion:

Normal measures for preventive fire protection.

Storage:

Store in the original receptacle, keeping this tightly sealed, under cool and dry conditions.

Further information:

Protect from sunlight, warmth and heat.

In order to ensure due transportation, make certain that stacks are of the correct height, containers are securely fastened so as not to fall off, and labelled according to the regulations.

In the event of internal transportation, already-opened containers are to be kept closed in order to avoid spillage.

German storage class:

12 - Non Combustible Liquids.

Transport information

Land transport (UN RTDG/ADR/RID)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Inland waterway transport (UN RTDG/ADN(R))

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not dangerous according to transport regulations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters:

Other information: Contains no substances with occupational exposure limit values.

DNEL/DMEL values:

Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

PNEC values:

Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

Exposure controls:

Engineering measures:

Provide for installation of emergency shower and eye bath.

Refill and handle product only in closed system.

Leak detection recommended.

Wastewater can be added to a biological wastewater treatment plant.

Remove exhaust gases through a washer or through combustion.

Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.

All precautionary measures indicated have to be observed.

Exposure controls:

The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH regulation.

Personal protective equipment:

Respiratory protection:

Use respiratory equipment with suitable filter or wear a self contained respiratory apparatus.

Suitable filter: A, code colour brown.

Accidental release measures:

Wear a self contained respiratory apparatus.

Note time limit for wearing respiratory protective equipment.

Hand protection:

Glove material: Nitrile

Material thickness: 0.2 mm

Method: DIN EN 374

Accidental release measures:

Glove material: Nitrile/Chloroprene:

Material thickness: 0.65 mm

Method: DIN EN 374.

Eye protection:

Safety glasses with side-shields conforming to EN166

or

When handling larger quantities:

Close-fitting protective goggles (e.g. closed goggles).

Skin and body protection:

Suitable protective clothing - Use disposable clothing if appropriate.

Hygiene measures:

Do not eat, drink, smoke, or sniff while at work.

Wash your hands and/or face before breaks and before termination of work.

Avoid contact with skin, eyes and clothing.

Remove and wash contaminated clothing before re-use.

Preventive skin protection is recommended.

Use barrier cream regularly.

Protective measures:

All precautionary measures indicated have to be observed.

Risk assessment and risk monitoring of all work places required.

Health, Safety and Emergency Management System recommended.

Regular safety training is a must.

Written approval necessary in case of non-routine jobs, e.g. maintenance activities.

The personal protective equipment used must meet the requirements of directive 89/686/EEC and amendments (CE certification).

It should be defined in the work place in the form of a risk analysis according to directive 89/686/EEC and amendments.

Environmental exposure controls:

In some cases, exhaust air scrubbers, filters or technical changes to the processing plant will be required in order to decrease emissions to acceptable values.

Stability and reactivity

Reactivity:

No further information available.

Chemical stability:

No further information available.

Possibility of hazardous reactions:

No hazardous reactions are known if properly handled and stored.

Conditions to avoid:

Keep away from direct sunlight.

Incompatible materials:

No further information available.

Hazardous decomposition products:

No further information available.

Disposal considerations

Waste treatment methods:

Product:

Strictly controlled conditions during disposal or treatment to air, wastewater and waste.

Wastewater can be added to a biological wastewater treatment plant.

Disposal according to local authority regulations.

Pack and label wastes like the pure substance.

Do not detach label from the delivery containers prior to disposal.

Uncleaned packaging:

Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.

Waste Key Number:

The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.