Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Jan-Jun 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: study performed according to OECD guideline and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Bottom product of propylene oxide and styrene production
IUPAC Name:
Bottom product of propylene oxide and styrene production
Details on test material:
- Name of test material (as cited in study report): KORE grade V
- Substance type: UVCB
- Physical state: Brown viscous liquid
- Stability under test conditions: months
- Storage condition of test material: room temperature

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic, non-adapted
Details on inoculum:
Prior to use a sample of activated sludge from the sewage plant at Taunusstein-Bleidenstadt was washed twice with mineral nutrient solution of the CO2-Evolution-Test to eliminate organic components and carbonates from the sludge. After resolution with mineral nutrient medium the sludge was aerated by means of compressed humidified air for about four hours. Before use as inoculum for the CO2-Evolution-Test the sludge was homogenised in a "Waring Blender" at low speed for 2 minutes and then filtered through a cotton filter previously carefully rinsed with deionised water. The filtrate was used as inoculum (1% of the final volume of the test solution) on the same day of preparation.
Duration of test (contact time):
ca. 28 d
Initial test substance concentrationopen allclose all
Initial conc.:
103.3 mg/L
Based on:
test mat.
Initial conc.:
104.4 mg/L
Based on:
test mat.
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
O2 consumption
Details on study design:
TEST CONDITIONS
- Composition of medium: as mentioned in the guideline
- Additional substrate: none
- Solubilising agent: none
- Test temperature: values were in the range of 19.6 to 21.3 °C (mean 20.1°C)
- pH: 7.4 ± 0.2 at t0
- pH adjusted: no
- Aeration of dilution water: the aeration rate of the test system was controlled at 4 L/h
- Continuous darkness: yes

TEST SYSTEM
- Culturing apparatus: ≈5-litre amber carboys served as test vessels. They were closed with stoppers with tubing for gas inlet and outlet (gas exit line)
- Number of culture flasks/concentration: two vessel with the test item, one vessel with sodiumbenzoate (control item), one toxicity control
- Method used to create aerobic conditions: aeration

SAMPLING
- Sampling frequency: Titrations were performed at t3d, t5d, t10d, t14d, t20d, t28d, and t29d
- Sample storage before analysis: data not available

CONTROL AND BLANK SYSTEM
- Inoculum blank: yes
- Abiotic sterile control: no
- Toxicity control: yes

STATISTICAL METHODS: not applicable
Reference substance
Reference substance:
benzoic acid, sodium salt
Remarks:
20 mg TOC/L

Results and discussion

% Degradation
Parameter:
other: O2 uptake in the test solutions
Value:
50.8
Sampling time:
28 d
Remarks on result:
other: mean value
Details on results:
The degradation process was followed by the oxygen uptake in the test solutions using two test solutions of the test item. With respect to the theoretical oxygen demand (ThOD) of the test item and the measured BOD of the test solutions a degradation value of 53% of the test item was measured within the first test solution using 103.3 mg/L of the test item after 28 days of incubation. 48.6% degradation was observed in the second test solution with 104.0 mg/L test item.
The calculated mean degradation value of the test item was 50.8 %.

BOD5 / COD results

Results with reference substance:
The control item sodium benzoate was degraded 88 %, the "10-days-window" being met within 5 days (68 %).

Any other information on results incl. tables

Degradation of the Test Item in the 1stTest Solution, 103.3 mg/L

Time (d)

Values read on the Display of the Respirometer (mg O2/L)1)

% Degradation

Blank 1

Blank 22)

Test Item

0.0

0

0

0

0.0

1.0

0

0

0

0.0

2.0

0

0

0

0.0

3.0

0

0

85

9.3

3.9

1

0

159

17.4

4.9

4

0

242

26.2

5.9

6

0

270

29.0

7.0

8

0

295

31.6

7.9

10

0

313

33.3

8.8

11

0

326

34.6

10.1

13

0

338

35.7

11.0

14

0

354

37.4

12.0

15

0

367

38.7

12.9

16

0

379

39.9

13.9

18

0

394

41.3

14.9

19

0

408

42.8

15.9

20

0

424

44.4

16.8

21

0

434

45.4

17.9

23

0

446

46.5

19.0

23

0

458

47.8

20.0

24

0

465

48.5

20.9

25

0

472

49.2

22.0

28

0

479

49.6

22.9

28

0

485

50.3

24.1

28

0

494

51.2

25.0

29

0

497

51.5

25.9

30

0

504

52.1

27.0

31

0

508

52.5

28.0

33

0

517

53.2

1)The indicated values are multiplied by factor 0.25 which is valid for the 1000 mL of volume.

2)not considered as there was an equipment error.  

 

Degradation of the Test Item in the 2ndTest Solution, 104.0 mg/L

Time (d)

Values read on the Display of the Respirometer (mg O2/L)1)

% Degradation

Blank 1

Blank 22)

Test Item

0.0

0

0

0

0.0

1.0

0

0

0

0.0

2.0

0

0

35

3.8

3.0

0

0

103

11.3

3.9

1

0

184

20.0

4.9

4

0

245

26.3

5.9

6

0

271

28.9

7.0

8

0

288

30.6

7.9

10

0

296

31.2

8.8

11

0

306

32.2

10.1

13

0

324

34.0

11.0

14

0

336

35.2

12.0

15

0

350

36.6

12.9

16

0

362

37.8

13.9

18

0

374

38.9

14.9

19

0

384

39.9

15.9

20

0

394

40.9

16.8

21

0

402

41.6

17.9

23

0

411

42.4

19.0

23

0

420

43.4

20.0

24

0

426

43.9

20.9

25

0

433

44.6

22.0

28

0

442

45.2

22.9

28

0

446

45.7

24.1

28

0

454

46.5

25.0

29

0

459

47.0

25.9

30

0

465

47.5

27.0

31

0

469

47.8

28.0

33

0

478

48.6

1)The indicated values are multiplied by factor 0.25 which is valid for the 1000 mL of volume.

2)not considered as there was an equipment error.

Degradation of the Toxicity Control

Time (d)

Values read on the Display of the Respirometer (mg O2/L)2)

% Degradation1)

Blank 1

Blank 23)

Toxicity Control

0.0

0

0

0

0.0

1.0

0

0

62

3.8

2.0

0

0

258

15.6

3.0

0

0

322

19.5

3.9

1

0

383

23.2

4.9

4

0

477

28.9

5.9

6

0

609

36.8

7.0

8

0

633

38.2

7.9

10

0

643

38.7

8.8

11

0

661

39.7

10.1

13

0

688

41.3

11.0

14

0

691

41.5

12.0

15

0

712

42.7

12.9

16

0

727

43.6

13.9

18

0

728

43.6

14.9

19

0

731

43.7

15.9

20

0

739

44.2

16.8

21

0

741

44.3

17.9

23

0

743

44.3

19.0

23

0

744

44.4

20.0

24

0

745

44.4

20.9

25

0

763

45.5

22.0

28

0

800

47.6

22.9

28

0

815

48.5

24.1

28

0

822

49.0

25.0

29

0

836

49.8

25.9

30

0

845

50.3

27.0

31

0

885

52.7

28.0

33

0

890

52.9

 

1)The basis for the biodegradation is the sum of ThODs of both the test item and sodium benzoate.

2) The indicated values are multiplied by factor 0.5 which is valid for the 500 mL of volume.

3)not considered as there was an equipment error.

With respect to the theoretical oxygen demand (ThOD) of the test item and the measured BOD of the test solutions a degradation value of 53% of the test item was measured within the first test solution using 103.3 mg/L of the test item after 28 days of incubation. 48.6% degradation was observed in the second test solution with 104.0 mg/L test item.The toxicity control showed >25% degradation within 14 days based on total ThOD, therefore the test substance is not considered to be inhibitory according to the OECD test guidelines 301.Regarding the results obtained within this study the test item should be considered "not readily biodegradable". The control item sodium benzoate was degraded 98% within 28d. The threshold of³60% was met within 5d (60.8%) of incubation. Therefore, the test is considered valid. An abiotic degradation can be excluded.

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
other: not readily biodegradable
Conclusions:
The test substance is not considered to be inhibitory.
The test item should be considered "not readily biodegradable"
Executive summary:

”KORE grade V“was tested for biodegradability according to ‘Manometric Respirometry Test' (OECD Guideline 301F).The degradation process was followed by the oxygen uptake in the test solutions using two test solutions of the test item. With respect to the theoretical oxygen demand (ThOD) of the test item and the measured BOD of the test solutions a degradation value of 53% of the test item was measured within the first test solution using 103.3 mg/L of the test item after 28 days of incubation. 48.6% degradation was observed in the second test solution with 104.0 mg/L test item.The toxicity control showed >25% degradation within 14 days based on total ThOD, therefore the test substance is not considered to be inhibitory according to the OECD test guidelines 301.Regarding the results obtained within this study the test item should be considered "not readily biodegradable". The control item sodium benzoate was degraded 98% within 28d. The threshold of³60% was met within 5d (60.8%) of incubation. Therefore, the test is considered valid. An abiotic degradation can be excluded.