Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: It is unknown if the vicosmeters were calibrated and the study was not done according to GLP guidelines and does not cite a test guidance.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
no guideline followed
Deviations:
not applicable
Principles of method if other than guideline:
Viscosity was measured using a Schott Viscosity Timer, temperature control bath, and viscometers: 545-00 and 545-03. Viscometer was corrected using the Hagenbach correction.
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Chemical structure
Reference substance name:
1,1,1,3,4,4,4-heptafluoro-3-(trifluoromethyl)butan-2-one
EC Number:
690-995-3
Cas Number:
756-12-7
Molecular formula:
C5 F10 O
IUPAC Name:
1,1,1,3,4,4,4-heptafluoro-3-(trifluoromethyl)butan-2-one
Details on test material:
- Name of test material (as cited in study report): L-21058
- Analytical purity: 99.89%

Results and discussion

Viscosity
Temp.:
other: 0.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.41
Remarks on result:
other: result reported as 0.41 cS

Any other information on results incl. tables

Kinematic Viscosity = exp (633.512904*1/ (T+211) - 3.894158)

Applicant's summary and conclusion

Conclusions:
The viscosity of CAS# 756-12-7 is 0.41 mm²/s at 0.0 °C
Executive summary:

The viscosity of CAS# 756-12-7 is 0.41 mm²/s at 0.0 °C. Measurements were made using calibrated Schott-Ubbelohde Viscometers: 545-00 and 545-03. It is unknown which viscometer(s) were used for this compound's viscosity measurements. The viscometer was corrected using the Hagenbach correction. The study addresses kinematic viscosity directly, and is therefore relevant to the viscosity endpoint. It is unknown if viscometers were calibrated. Although the viscometers used in this study are compliant with ASTM D2515 and ASTM D446 standards, it is unknown if this study followed an ISO, ASTM, or OECD guideline. The study was not conducted in accord with GLP guidelines. Therefore the study is classified reliable with restrictions.