Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D446/07
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Reference substance name:
Alkenes, C13-14, hydroformylation products, low boiling
EC Number:
932-284-5
Molecular formula:
Not available-not a single isomer - see remarks
IUPAC Name:
Alkenes, C13-14, hydroformylation products, low boiling
Details on test material:
Name of test material (as cited in study report): Alkenes, C13-14, hydroformylation products, low boiling

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 3.552
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 2.353

Any other information on results incl. tables

CALIBRATION

(repeat determination)

SUBSTANCE USED FOR CALIBRATION: Nonane NQS08004

CALIBRATION TEMPERATURE: 25.0 °C / 25.0 °C

KINEMATIC VISCOSITY (THEORY): 0.93 mm2/s / 0.93 mm2/s

VISCOSIMETER CONSTANT: 0.005381 / 0.005381

MEASURED FLOW TIME: 172.8 sec / 172.8 sec

KINEMATIC VISCOSITY (EXPERIMENTAL): 0.93 mm2/s // 0.93 mm2/s

MEASUREMENT

(repeat determination)

TEMPERATURE: 20.0 °C / 20.0 °C (40 °C / 40 °C)

VISCOSIMETER CONSTANT: 0.005381

MEASURED FLOW TIME: 660.14 sec / 660.25 sec (473.37 sec / 473.34 sec)

KINEMATIC VISCOSITY: 3.5522 mm2/s / 3.5528 mm2/s (2.3537 mm2/s / 2.3533 mm2/s)

KINEMATIC VISCOSITY AVERAGE: 3.5525 mm2/s (2.3535 mm2/s)

Applicant's summary and conclusion

Executive summary:

Alkenes, C13-14, hydroformylation products, low boiling is measured according to ASTM D446/07. The viscosity is determind to be 3.5525 mm²/s at 20 °C and 2.3535 mm²/s at 40 °C.