Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
None
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Principles of method if other than guideline:
None
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
GHS criteria not met
Conclusions:
No ignition was observed throughout the course of the test. Hence, the test item FAT 40032/G should be considered as not highly flammable.
Executive summary:

The flammability of the test substance was evaluated in a study conducted according to EU Method A.10. The substance did not ignite or propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period. Hence, the test item FAT 40032/G should be considered as not highly flammable.

Description of key information

The test item FAT 40032/G should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of the test substance was evaluated in a study conducted according to EU Method A.10. The substance did not ignite or propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period. Hence, the test item FAT 40032/G should be considered as not highly flammable.

Justification for classification or non-classification

No ignition was observed throughout the course of the test. The test item FAT 40032/G should be considered as not highly flammable. Therefore, no classification is warranted according to CLP (1272/2008) Regulation.