Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
other: Statement based on the structure of the test item according to international guidelines
Adequacy of study:
key study
Study period:
From 22 December 2015 to 12 December 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6316 (Explodability)
Version / remarks:
1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: • United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Part I: Classification Procedures, Test Methods and Criteria Relating to Explosives of Class 1, Section 13: “Test Series 3”, 2009.
Version / remarks:
2009
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: • United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Appendix 6: “Screening Procedures”, 2009.
Version / remarks:
2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not measured/tested
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not measured/tested

Based on the composition of the test item and the absence of chemical group associated with explosives properties, the test item is considered to no possess explosives properties.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item is not consider to possess explosives properties
Executive summary:

A statement was performed to conclude on the explosives properties on the test item.

This statement have been done according to recognized guidelines (United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5 Section 13: “Test Series 3”, 2009; United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5 Appendix 6: “Screening Procedures”, 2009; EU method A.14 and EPA OPPTS 830.6316) and under GLP. No deviation from the guidelines was observed during the test.

Based on the composition of the test item and the absence of chemical group associated with explosives properties, the test item is considered to no possess explosives properties.

Description of key information

A statement was performed to conclude on the explosives properties on the test item.

This statement have been done according to recognized guidelines (United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5 Section 13: “Test Series 3”, 2009; United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5 Appendix 6: “Screening Procedures”, 2009; EU method A.14 and EPA OPPTS 830.6316) and under GLP. No deviation from the guidelines was observed during the test.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

Based on the composition of the test item and the absence of chemical group associated with explosives properties, the test item is considered to no possess explosives properties.