Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Ensure supply of fresh air. If necessary consult a

physician.

Emergency measure - Eyes: Flush eyes with plenty of clean running water for 15 minutes

or more. Consult a physician.

Emergency measure - Skin: Wash skin with soap and water. In necessary consult a

physician.

Emergency measure - Ingestion: Immediately drink a large quantity of milk or water. Call a

physician.

Fire-fighting measures

Recommended extinguishing agent: Water, carbon dioxide or dry chemical.

Product arising from burning: The substance is combustible and will burn if involved in

a fire, evolving noxious fumes (e.g carbon and nitrogen

oxides and vanadium containing compounds).

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Personal precautions:

Use rubber gloves for handling spills.

Environmental precautions:

Prevent spills from entering sewer or waterway.

Method for cleaning up:

Sweep up spills not raising dust, and place them in a

covered container for disposal.

Handling and storage

Handling: The substance should be stored, handled and used under

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical protective clothing to Standard EN368

Eye protection to Standard EN166.

Furthermore, when respiratory protective equipment has to be

used, it must be capable of adequately controlling exposure,

be suitable for the purpose, and conform to the appropriate

international or national standards, such as a dust mask

conforming to EN149 FFP1.

These measures should be regarded as a minimum.

Storage: Store in a cool dark room. Seal container is recommended.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: 2L polyethylene bottle. Seal container is recommended.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None.
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Keep away from strong oxidising materials.

Chemical reaction with water: None which is hazardous.

Dust explosion: Under normal conditions of use this material does not

present a significant explosion hazard. However, like most

organic compounds it is combustible and may form a dust

explosion if widely dispersed in air.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery from minor spillages or accidental discharge is not

economically or technically feasible, and such waste

material will be disposed of by incineration. In

principle, it may be possible to recover larger

spillages of uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: The notification tests have shown that the substance is not

classified at the VIIC notification level.

The dust hazard will be minimised by appropriate handling

and storage.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning

under controlled conditions at a licensed waste treatment

processor in accordance with local regulations. Stack gases

should be scrubbed, because noxious fumes (eg. carbon and

nitrogen oxides and vanadium containing compounds) could be

formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly

tothe sewage system or the aqueous environment.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: Not applicable as the substance is irreversibly bound to a

matrix in a film.