Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 478-950-4 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- (Q)SAR
- Adequacy of study:
- key study
- Study period:
- 2017-02-20
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- 1. SOFTWARE
iSafeRat® toolbox – in Silico Algorithms For Environmental Risk And Toxicity version 2.2
2. MODEL (incl. version number)
iSafeRat® holistic HA-QSAR v1.7
3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
C1C(CCC)COC(=O)C1
4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached QMRF
5. APPLICABILITY DOMAIN
See attached QPRF:
6. ADEQUACY OF THE RESULT
See attached QPRF - Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Deviations:
- not applicable
- Remarks:
- QSAR model
- Principles of method if other than guideline:
- The purpose of the in silico study was to determine the water solubility of test item in pure water at 25°C. The determination was performed using a Quantitative Structure-Property Relationship (QSPR) model which have been validated as QSAR models to be compliant with the OECD (2004) recommendations for QSAR modeling (refer to the QMRF with JRC QMRF identifier: Q19-46-51-448 for further details). This model is applicable for the substances generally classified as MOA 1 substances (non-polar narcotics) and ethers, esters, ketones, aldehydes, alcohols, acids and phenols. The algorithm is based on a regression method in which validated log Kow values are plotted against the log of sub-cooled liquid water solubility from studies of high quality. These have been carried out using one of the methods recommended in the OECD 105 guideline or an adaptation of these.
- GLP compliance:
- no
- Specific details on test material used for the study:
- not applicable
- Key result
- Water solubility:
- 26 128 mg/L
- Temp.:
- 25 °C
- Remarks on result:
- other: pH not determinable by QSAR calculation
- Details on results:
- - Descriptor domain: The log KOW used as descriptor for this prediction was calculated and it falls within the descriptor domain of the model between log KOW of 0.03 to 5.52. The test substance falls within the response domain of the training set between log water solubility (in log (mol/l)) of 0.88 to -5.38.
- Structural fragment domain: Currently, the water solubility module of the iSafeRat® Holistic HA-QSAR can reliably predict the water solubility for chemicals generally classified as MOA 1 substances (non-polar narcotics) and ethers, esters, ketones, aldehydes, alcohols and acids. 5-propyl-tetrahydropyran-2-one as an ester can be taken into account for water solubility prediction. All chemical groups within the molecular structure are taken into account by the model.
- Mechanism domain: Water solubility of the substance is determined using log KOW as descriptor. The submodel used is depending of the capability of the substance to participate in hydrogen bonding with water and octanol. iSafeRat® Holistic HA-QSAR includes the following submodels:
- Water Solubility submodel for NonPolar Organic compounds: for compounds which are neither donor, nor acceptor for hydrogen bonds (e.g. al kanes, halides, alkenes, thiols… etc.)
- Water Solubility submodel for Oxygenated, NonHydroxylated compounds (classical): for hydrogen bond acceptor compounds which are not do nors (e.g. ethers, mono-esters, ketones, aldehydes, epoxides, lactones, carbonates, (meth)acrylates)
- Water Solubility submodel for Oxygenated, NonHydroxylated compounds (diesters): specific sub-model for diesters compounds.
- Water Solubility submodel for Oxygenated, Hydroxylated compounds: for hydrogen bond acceptor and donor compounds (i.e. alcohols, ethoxyl ated alcohols, lactates and carboxylic acids).
CONCLUSION: Test item falls within the applicability domain of the model and was therefore reliably predicted for its water solubility. Therefore, this endpoint value can be considered valid and fit for purpose. - Conclusions:
- Very soluble in water.
- Executive summary:
A Quantitative Structure-Property Relationship (QSPR) model was used to calculate the water solubility of the test item. This calculation method predicts the endpoint value which would be expected when testing the substance under experimental conditions in a laboratory following Guideline for Testing of Chemicals No. 105, "Water Solubility". The criterion predicted was the solubility in pure water in mg.L-1 at 25°C.
The determination was performed using a regression method in which validated log KOW values are plotted against the log of sub-cooled liquid water solubility from studies of high quality. These have been carried out using one of the methods recommended in the OECD 105 guideline or an adaptation of these.
Using the calculated log Kow value of 1.3, the water solubility is predicted as follows: 26128 mg/L at 25°C (95% CL 22148 - 30824 mg/L).
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- disregarded due to major methodological deficiencies
- Study period:
- 03-25 April 2006
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- significant methodological deficiencies
- Remarks:
- The determination was conducted with the column elution method, which is not suitable for a liquid test substance, and surface-active behaviour is suspected. Therefore validation cannot be granted.
- Reason / purpose for cross-reference:
- reference to other study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- signed 24 February 2006
- Type of method:
- column elution method
- Water solubility:
- 19 mg/L
- Incubation duration:
- >= 16 - <= 19 h
- Temp.:
- 20 °C
- pH:
- 6.6
- Executive summary:
The water solubility of the test substance was determined under GLP according to EU A.6 guideline, elution method.
In the preliminary testing, no saturation concentration could be determined, suggesting surface-active potential. The main test fulfilled the validity criteria, and the average value was retained. However, reliability is highly questionable.
As this method is considered not suitable for liquid test items, the solubility result was not retained.
But the information on the pH of the solution is considered of scientific interest : ca 6.6 at 19 mg/L.
Referenceopen allclose all
The 95% confidence interval (α = 0.05) for the result is 22148 – 30824 mg/L.
Preliminary assessments were aimed at the estimation of the hydrosolubility with no success: it was this suspected that the test item was able to form micro-drops of oily matter in suspension in water, and analysis of the hydrosolubility was not feasible. The micro-elution method was thus justified, even though final hydrosolubility was higher than 10 mg/L recommended for this testing method as a maximum.
Experiment n°1 - 25 mL/h flow rate
A 4.0103g sand portion was coated with 256.9 mg of test item. A sample of 1.0219g was introduced in the micro-column thus corresponding to 65 mg of test item.
About 31 mg of the test item were controlled to be voided in the rinsed volume (15 mL).
A total of five successive samples were submitted to the analysis which corresponded to the elution throughout a 16-h period.
Mean concentration in water = 17.9 (+/- 1.7) mg/L.
pH of the resulting solution = 6.62
Experiment n°2 - 13 mL/h flow rate
The micro-column was charged with a new 1 g sample of coated sand. About 30 mg test item were controlled to be voided in the rinsed volume (15 mL).
A total of five successive samples were submitted to the analysis which corresponded to the elution throughout a 19-h period.
Mean concentration in water = 20.8 (+/- 1.9) mg/L.
pH of the resulting solution = 6.59
Description of key information
Calculated water solubility ca 26.1 g/L at 25°C.
Considered as very soluble in water.
pH of a 19 mg/L solution ca 6.6.
Key value for chemical safety assessment
- Water solubility:
- 26.1 g/L
- at the temperature of:
- 25 °C
Additional information
An experimental study, conducted according to EC guideline and under GLP, is available, but the method used (elution) was not suitable. Moreover, preliminary testing and inconsistency with experimental partition coefficient suggest that the substance may exhibit surface-activity, despite the structural formula shows no alert. The final test fulfilled the validity criteria, but reliability cannot be granted.
However the pH of the resulting solution was included as supporting scientific information of interest.
Therefore, a calculation from a fully valid QSAR was additionally performed.
Due to experimental issues and inconsistencies, the calculated value was prefered, and retained as key data.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.