Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: If symptomatic, move to fresh air. Treat symptomatically.

Get medical attention if symptoms occur.

En cas de symptômes, sortir au grand air. Traiter de façon

symptomatique. Consulter un médecin en cas de symptômes.

Emergency measure - Eyes: Any material that contacts the eye should be washed out

immediately with water. Get medical attention if symptoms

occur.

Toute substance en contact avec l'oeil devrait être enlevée

par lavage immédiat a l'eau. Consulter un médecin en cas de

symptômes.

Emergency measure - Skin: Wash off with soap and water. Get medical attention if

symptoms occur.

Laver avec de l'eau et du savon. Consulter un médecin en cas

de symptômes.

Emergency measure - Ingestion: Seek medical advice.

Never give anything by mouth to an

unconscious person.

Fire-fighting measures

Recommended extinguishing agent: Water spray, carbon dioxide (CO2), dry chemical.

eau pulvérisée, dioxyde de carbone (CO2), poudre

d'extinction.

Product arising from burning: Hazardous Combustion Products:  Carbon oxides and oxides

of nitrogen

Produits de combustion dangereux:

Oxydes de carbone, oxydes d'azote (NOx)

Hazardous Decomposition Products:  Hydrogen chloride

Produits de décomposition dangereux:

Info on hazardous composition products (for comma delimited

phrases)

acide chlorhydrique.

Product determined by test: N

Protective equipment: Wear self-contained breathing apparatus and protective

clothing. Fire or excessive heat may produce hazardous

decomposition products.

Procédures spéciales de lutte contre l'incendie:

Porter un appareil respiratoire autonome et des vêtements de

protection. Le feu ou la chaleur excessive peut donner des

produits de décomposition dangereux.

Accidental release measures

Emergency measures in case of spillage: Shovel into suitable container for disposal. Avoid

dust formation. Clean contaminated surface

thoroughly.

Collecter dans des récipients appropriés pour élimination.

Eviter toute formation de poussières. Nettoyer soigneusement

la surface contaminée.

Handling and storage

Handling: Avoid prolonged or repeated breathing of dust. Avoid contact

with eyes and prolonged or repeated contact

with skin.  Ensure adequate ventilation. Wash

thoroughly after handling.

Storage: Keep container tightly closed. Keep away from

incompatible  substances (strong oxidizing

agents).

Packaging of the substance and or preparation: The substance will be imported into the Chalon company plant

sites in sealed, poly-lined fiber containers.  The

containers shall contain the warning:

Classification:  Dangerous for the environment

R53 - May cause long-term adverse effects in the aquatic

environment.

S61 - Avoid release to the environment.  Refer to special

instructions/safety data sheet.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
Transport: Not regulated for all modes of transportation.


Non réglementé pour tous modes de transport.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Fire or high temperatures may cause decomposition.

Dust may form explosive mixture in air.

Le feu ou des températures élevées peuvent provoquer la

décomposition. Les poussières peuvent former un mélange

explosif avec l'air.

Chemical reaction with water: Experience in use and structure activity relationships

indicate that the test substance is not hazardous in contact

with water or humid air.

Dust explosion: There are no data or experience indicating this substance

presents a dust explosion hazard; however no testing has

been conducted to characterize its dust explosibility

properties.  Fines of this substance, like those of many

organic dusts, may be capable of forming explosible dust

clouds in air.  Minimize dust generation and accumulation.

Keep away from sources of ignition.  Use adequate

ventilation.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: It is not practical to recover or recycle the substance

Industry - Possibility of neutralisation: It is not practical to neutralize the substance

Industry - Possibility of destruction: controlled discharge: Not recommended

Industry - Possibility of destruction - incineration: A temperature of 1000 degrees C is expected

to be sufficient to destroy the substance.

Hazardous combustion products include carbon oxides

and nitrogen oxides.  Hazardous decomposition

products include hydrogen chloride.

Industry - Possibility of destruction - water purification: The biodegradability and log Kow value of the substance were

measured in the testing laboratory.  These studies

determined that the substance cannot be classified as

readily biodegradable and that the log Kow value is >7.8.

Quantitative Structure-Activity Relationship (QSAR) programs

were used to estimate a Henry's Law Constant (HENRYWIN

v3.1) value of 3.59E-20 Pa-m3/mole.  Based on the results

from the biodegradation test, the measured log Kow value,

and the estimated log H value, the SIMPLETREAT 3.0 model

(Struijs, 1996) predicts at least 85% removal of the

substance during wastewater treatment.  Therefore, the

estimated amounts of substance discharged from the Station

de l'AUZIN treatment facility annually were estimated to be

1.09 kg (10436 mg/operation day) based upon intended

imported volumes and 2.17 kg (20872 mg/operation day) using

the maximum tonnage for a Level VIIB notification.

The local predicted environmental concentrations (PEC local

water) for the intended imported amount and maximum tonnage

for a Level VIIB notification were calculated to be

2.98E-6 mg/L and 5.96E-6 mg/L, respectively, based upon the

combined daily average flows of the Station de l'AUZIN waste

treatment plant (5E6 L/day) and the low flow of the Saone

River (3.5E9 L/day).

Industry - Possibility of destruction - other: None

Public at large - Possibility of recovery/recycling: It is not practical to recover or recycle the substance.

Public at large - Possibility of neutralisation: It is not practical to neutralize the substance.

Public at large - Possibility of destruction: controlled discharge: Not recommended.

Public at large - Possibility of destruction - incineration: A temperature of 1000 degrees C is expected

to be sufficient to destroy the substance.

Hazardous combustion products include carbon oxides

and nitrogen oxides.  Hazardous decomposition

products include hydrogen chloride.

Public at large - Possibility of destruction - water purification: The biodegradability and log Kow value of the substance were

measured in the testing laboratory.  These studies

determined that the substance cannot be classified as

readily biodegradable and that the log Kow value is >7.8.

Quantitative Structure-Activity Relationship (QSAR) programs

were used to estimate a Henry's Law Constant (HENRYWIN

v3.1) value of 3.59E-20 Pa-m3/mole.  Based on the results

from the biodegradation test, the measured log Kow value,

and the estimated log H value, the SIMPLETREAT 3.0 model

(Struijs, 1996) predicts at least 85% removal of the

substance during wastewater treatment.  Therefore, the

estimated amounts of substance discharged from the Station

de l'AUZIN treatment facility annually were estimated to be

1.09 kg (10436 mg/operation day) based upon intended

imported volumes and 2.17 kg (20872 mg/operation day) using

the maximum tonnage for a Level VIIB notification.

The local predicted environmental concentrations (PEC local

water) for the intended imported amount and maximum tonnage

for a Level VIIB notification were calculated to be

2.98E-6 mg/L and 5.96E-6 mg/L, respectively, based upon the

combined daily average flows of the Station de l'AUZIN waste

treatment plant (5E6 L/day) and the low flow of the Saone

River (3.5E9 L/day).

Public at large - Possibility of destruction - others: None