Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
not specified
GLP compliance:
not specified
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
95 °C
Atm. press.:
101.325 kPa

Average flash point: 95 ± 0.7 °C at 101.325 kPa

Standard deviation: 0.7 °C

Measurement 1: 94 °C at 99.34 kPa

Measurement 2: 95 °C at 99.34 kPa

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ISO 13736 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
Version / remarks:
1997
Principles of method if other than guideline:
E DIN EN ISO 13736
Type of method:
closed cup
Flash point apparatus:
Abel apparatus
Flash point:
95 °C
Atm. press.:
1 013 hPa
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Principles of method if other than guideline:
A Tag Closed cup method was used
GLP compliance:
no
Type of method:
closed cup
Flash point:
94 °C
Atm. press.:
760 mm Hg

Description of key information

94 °C to 104 °C at 101.325 kPa

(several materials were tested according to ISO 2719, Pensky-Martens closed cup or ISO 13736, Abel closed cup)

Key value for chemical safety assessment

Additional information

The reported values for the flash point for Tar acids, xylenol fraction range from 94 -104 °C. The flash point of the substance will vary depending on the ratio of the constituents of the substance.