Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Surface tension

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given
Qualifier:
according to guideline
Guideline:
other: DIN 53914
Principles of method if other than guideline:
Wilhelmy plate method is used to measure the surface tension using a standardized plate with a plate tensiometer. The plate is moved towards the surface until the meniscus connects with it. The surface tension is calculated from the resulting force. Due to uncertain wetting behaviour, the plate can only be used for interfaces under certain limitations.
GLP compliance:
no
Type of method:
plate method
Key result
Surface tension:
20 mN/m
Temp.:
25 °C
Conc.:
100 vol%
Conclusions:
Under the conditions of this study a surface tension of 20 mN/m at 25 °C was determined for the test substance, isoheptane.
Executive summary:

Under the conditions of this study a surface tension of 20 mN/m at 25 °C was determined for the test substance, isoheptane.

Description of key information

The surface tension range of isoheptane is 17 to 21 mN/m at 25°C.

Key value for chemical safety assessment

Additional information

Surface tension is measured using a Wilhelmy plate. A range of 17 to 21 mN/m covers all possible grades within this substance description if measured with the agreed method. A test conducted by DHC (2010) using a Wilhelmy plate according to DIN 53914 demonstrates that the measured value of 20 mN/m at 25°C falls within these borderline values.