Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-06-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
2006
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell
Key result
Temp.:
25 °C
Vapour pressure:
1.318 Pa
Temp.:
20 °C
Vapour pressure:
0.967 Pa
Vapour pressure:
0.022 Pa

The vapour pressure was measured in the temperature range of 30 to 60 °C. As no reproducible mass loss was achieved at 30 °C, the evaluation of the vapour pressure was performed in the range of 35 to 60 °C. The measured vapour pressure values together with the measured temperatures and the regression data of the vapour pressure curve can be seen in Tables 1 and 2, respectively.


 


Table 1. Results of the Effusion method









































Temperature, °C



Δm/Δt, mg/min



Vapour pressure, Pa



35.1



1.2991 x 10-2



2.7457



40.0



1.4707 x 10-2



3.1333



45.1



1.6330 x 10-2



3.5070



50.1



2.2191 x 10-2



4.8031



55.1



3.3167 x 10-2



7.2336



60.1



4.5380 x 10-2



9.9729



 


Table 2. Regression data of the vapour pressure curve - Regression output
















Intercept



Slope



R. Squared



8.0021



-2350.0733



0.9417


Conclusions:
The vapour pressure of the test item was determined to be 1.318 Pa at 25 °C.
Executive summary:

An experimental study was conducted to determine the vapour pressure of the test item according to Regulation (EC) No. 440/2008 Method A.4. and OECD Test Guideline 104 (2006) using the effusion method (Knudsen cell). The vapour pressure at 20 and 25 °C was extrapolated from the linear regression of the vapour pressure curve of the measurements performed in the range of 30 to 60 °C. The vapour pressure of the test item was determined to be 0.967 Pa and 1.318 Pa at 20 and 25 °C, respectively.

Description of key information

The vapour pressure of the test item was determined to be 1.318 Pa at 25 °C.

Key value for chemical safety assessment

Vapour pressure:
1.318 Pa
at the temperature of:
25 °C

Additional information

An experimental study was conducted to determine the vapour pressure of the test item according to Regulation (EC) No. 440/2008 Method A.4. and OECD Test Guideline 104 (2006) using the effusion method (Knudsen cell). The vapour pressure at 20 and 25 °C was extrapolated from the linear regression of the vapour pressure curve of the measurements performed in the range of 30 to 60 °C. The vapour pressure of the test item was determined to be 0.967 Pa and 1.318 Pa at 20 and 25 °C, respectively.