Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell
Specific details on test material used for the study:
Test Item: RCX 15-116
Chemical name: Tris(N-hydroxy-N-nitosophenylaminato-O,O’)aluminium
CAS No.: 15305-07-4
EC No.: 239-341-7
Appearance: Whitish to pale yellow powder
Batch No.: 16008AE2
Purity: 99.1 %
Certificate of analysis: Certificate of analysis of GENORAD* 19 from Rahn AG, Dörflistrasse 120, CH-8050 Zürich, Switzerland dated 2016-04-12 and MSDS of RCX 15-116
Storage conditions: Ambient temperature (< 40 °C), keep container tightly closed, protected from sunlight
Expiry date: 2018-02
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0 Pa
Remarks on result:
other: calculated
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: calculated
Key result
Test no.:
#3
Temp.:
50 °C
Vapour pressure:
0 Pa
Remarks on result:
other: calculated
Executive summary:

The objective of this study was the determination of the vapour pressure of the test item by the Effusion method (Knudsen cell). Up to a temperature of 120 °C no vapour pressure could be detected. The vapour pressure was measured in the temperature range of 120 to 150 °C. The vapour pressure of the test item RCX15-116 was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20, 25 and 50 °C, according to Regulation EC No. 440/2008 Method A.4.Vapour Pressure and OECD Test Guideline 104 (2006).

Temperature / °C            Vapour pressure / Pa

20                                      9.3 × 10-7

25                                      1.5 × 10-6

50                                      1.2 × 10-5

Description of key information

The objective of this study was the determination of the vapour pressure of the test item by the Effusion method (Knudsen cell). Up to a temperature of 120 °C no vapour pressure could be detected. The vapour pressure was measured in the temperature range of 120 to 150 °C. The vapour pressure of the test item RCX15-116 was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20, 25 and 50 °C.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information