Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

GENERAL INFORMATION

In case of accident or if you feel unwell, seek medical advice immediately.

AFTER INHALATION

Supply fresh air and to be sure call for a doctor.

AFTER SKIN CONTACT

Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

AFTER EYE CONTACT

Rinse opened eye for several minutes under running water. Then consult a doctor.  

AFTER SWALLOWING

Rinse out mouth and then drink plenty of water. Call a doctor immediately.    

Fire-fighting measures

EXTINGUISHING MEDIA

Suitable extinguishing agents: CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

For safety reasons unsuitable extinguishing agents: Water with full jet.

Special hazards arising from the substance or mixture: In case of fire, carbon monoxide (CO), acetylacetone, acetone and acetic acid, can be produced.  

ADVICE FOR FIREFIGHTERS

Protective equipment: Wear self-contained respiratory protective device and fully protective suit.

Accidental release measures

PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES

The usual precautionary measures are to be adhered to when handling chemicals. Wear protective equipment. Keep unprotected persons away. Avoid formation of dust.

ENVIRONMENTAL PRECAUTIONS

Do not allow to enter sewers/surface or groundwater Do not allow to penetrate the ground/soil.

METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP

Pick up mechanically. Send for recovery or disposal in suitable receptacles.

Handling and storage

PRECAUTIONS FOR SAFE HANDLING

Wear protective equipment. Keep unprotected persons away. The usual precautionary measures are to be adhered to when handling chemicals. Avoid contact with the substance. Prevent formation of dust.

INFORMATION ABOUT FIRE -AND EXPLOSION PROTECTION:

Dust can combine with air to form an explosive mixture. Keep ignition sources away. Do not smoke. Protect from heat. Protect against electrostatic charges.

CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES

Requirements to be met by storerooms and receptacles: Store in cool conditions

Information about storage in one common storage facility: Not required.  

Further information about storage conditions: Store under inert gas. Keep container tightly sealed. Protect from heat and direct sunlight.

Recommended storage temperature: ≤ 25°C

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN3181
Shipping information
Proper shipping name and description:
3181 METAL SALTS OF ORGANIC COMPOUNDS, FLAMMABLE, N.O.S. (Bis(acetylacetonato)palladium(II))
Chemical name:
Bis(acetylacetonato)palladium(II)
Language:
English
Labels:
4.1
Special provisions / remarks
Special provisions:
Limited Quantities (LQ): 5kg
Transport category: 3
Tunnel restriction code: 3
Remarks:
Warning: Flammable solids, self-reactive substances and solid desensitised explosives
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN3181
Shipping information
Proper shipping name and description:
METAL SALTS OF ORGANIC COMPOUNDS, FLAMMABLE, N.O.S. (Bis(acetylacetonato)palladium(II))
Chemical name:
Bis(acetylacetonato)palladium(II)
Labels:
4.1
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN3181
Shipping information
Proper shipping name and description:
METAL SALTS OF ORGANIC COMPOUNDS, FLAMMABLE, N.O.S. (Bis(acetylacetonato)palladium(II))
Chemical name:
Bis(acetylacetonato)palladium(II)
Labels:
4.1
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Additional information about design of technical facilities: Ensure good ventilation/exhaustion at the workplace.

GENERAL PROTECTIVE AND HYGIENIC MEASURES

- The usual precautionary measures are to be adhered to when handling chemicals

- Do not eat, drink, smoke or sniff while working

- Avoid contact with the eyes and skin

-Use dust proof working clothing

- Respiratory protection: Use Air-stream helmet with cover and respiration protection filter A/P3 (e.g. product from 3M model HT-125)

- Protection of hands: Protective gloves.

- The glove material has to be impermeable and resistant to the product/the substance/the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation.

- Material of gloves: the selection of the suitable glove does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.

- Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

- For the permanent contact gloves made of the following material are suitable: Fluorocarbon rubber (Viton)

- Eye protection: Use Air-Stream helmet with cover and respiration protection filter A/P3 (e.g. product from 3M model HT-125)

- Body protection: Because the material has sensitising potential, use a completely dust proof protective clothing (dust-proof one-way overall with integrated hood, air-stream helmet for protection of the face and the neck, working boots).  

Stability and reactivity

- Thermal decomposition / conditions to be avoided: To avoid decomposition do not overheat. Prevent formation of dust.

- Decomposition starts at: > 185°C

- Possibility of hazardous reactions: No dangerous reactions known

- Conditions to avoid: No further relevant information available

- Incompatible materials: No further relevant information available.

- Hazardous decomposition products: Acetylacetone.

Disposal considerations

WASTE TREATMENT METHODS

Contact manufacturer for recycling information. Disposal must be made according to official regulations.

UNCLEANED PACKAGING

Disposal must be made according to official regulation