First-aid measures

General: Move into fresh air and keep at rest. Get medical attention immediately

Inhalation: Move the exposed person to fresh air at once. If respiratory problems, artificial respiration/oxygen. Call a physician or poison control center immediately.

Eye contact: Immediately rinse with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Call a physician or poison control center immediately.

Skin contact: Remove contaminated clothing immediately and wash skin with soap and water. Get medical attention promptly if symptoms occur after washing. Wash contaminated clothing before reuse.

Ingestion: If conscious, drink plenty of water. Do not induce vomiting. Call a physician or poison control center immediately.

Most important symptoms and effects, both acute and delayed:

Product may hydrolyse upon contact with body fluids in the gastrointestinal tract to produce additional methanol; therefore, consider the signs/symptoms of methanol poisoning and also observe the known latency period of several days.

Fire-fighting measures

General fire hazards: Do not use water jet as an extinguisher, as this will spread the fire. Use

water spray to keep fire-exposed containers cool.

Suitable extinguishing media: Alcohol resistant foam. Carbon dioxide Dry chemical

Unsuitable extinguishing media: Avoid water in straight hose stream; will scatter and spread fire

Special hazards arising from the substance or mixture: In case of fire, carbon monoxide and carbon dioxide may be formed

Special fire-fighting procedures: Take precautionary measures against static discharges. To prevent and minimize fire or explosion risk from static accumulation and discharge, effectively bond and/or ground product transfer system.

Special protective equipment for fire-fighters: Wear self-contained breathing apparatus and protective clothing.

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Avoid contact with eyes, skin, and clothing. Avoid contact with liquid and vapors. Use personal protective equipment

Environmental precautions: Do not allow runoff to sewer, waterway or ground

Methods and materials for containment and cleaning up: Absorb spillage with suitable absorbent material. Shovel up and place in a container for salvage or disposal

Remove sources of ignition. In case of spills, beware of slippery floors and surfaces. Collect and dispose of spillage as indicated in relevant section.

Handling and storage

Precautions for safe handling: Do not taste or swallow. Avoid contact with eyes, skin, and clothing. Wash hands after handling. Provide adequate ventilation. Avoid inhalation of dust and vapors.

Storage conditions: Keep container tightly closed. Keep away from sources of ignition - No smoking

Conditions for safe storage, including any incompatibilities: Keep container tightly closed. Keep away from sources of ignition - No smoking.

Storage stability: Material is stable under normal conditions

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
This product is not regarded as dangerous goods according to the national and international regulations on the transport of dangerous goods.
Keep away from foodstuffs and animal feed.

Exposure controls / personal protection

Appropriate engineering controls: Provide eyewash station and safety shower. General (mechanical) room ventilation is expected to be satisfactory if handled at low temperatures or in covered equipment. Provide adequate ventilation if fumes or vapors are generated.

Individual protection measures, such as personal protective equipment

General information: Use only in well-ventilated areas. Do not eat, drink or smoke when using the product. Wash hands after handling. Practice good housekeeping.

Eye/face protection: Safety glasses with side-shields conforming to EN166

Hand protection: Advice: This recommendation is valid only for our Product as delivered. If this product will be mixed with other substances you need to contact a supplier of CE approved protective gloves.

Minimum break through time: 480 min

Glove thickness: 0,7 mm

Guideline: EN 374

Other: Safety shoes Wear suitable protective clothing

Respiratory protection: Respirator with a vapour filter (EN 141) Avoid inhalation of vapors. In case of inadequate ventilation, use air-supplied full-mask.

Hygiene measures: Avoid contact with eyes. When using do not smoke. Wash thoroughly after handling.

Environmental exposure controls: No release to wastewater from process as such, wastewater emissions limited to release generated from final equipment cleaning step using water

Stability and reactivity

Reactivity: No data available

Chemical stability: Material is stable under normal conditions

Possibility of hazardous reactions: Hazardous polymerisation does not occur

Conditions to avoid: Keep away from heat, sparks and open flame. High Temperatures Keep away from moisture.

Incompatible materials: Oxidising agents. Contact with water.

Hazardous decomposition products: Carbon oxides. Oxides of silicon. Nitrogen oxides.

Disposal considerations

General information: See section on information on appropriate personal protective equipment. The generation of waste should be avoided or minimized wherever possible. Do not discharge into drains, water courses or onto the ground.

Disposal methods: Can be incinerated when in compliance with local regulations