First-aid measures

Description of first aid measures
First aid personnel should pay attention to their own safety. If the patient is likely to become unconscious, place and transport in stable sideways position (recovery position). Immediately remove contaminated clothing.


 


If inhaled:
Keep patient calm, remove to fresh air, seek medical attention. Immediately administer a corticosteroid from a controlled/metered dose inhaler.


 


On skin contact:
Immediately wash thoroughly with plenty of water, apply sterile dressings, consult a skin specialist.


 


On contact with eyes:
Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open, consult an eye specialist.


 


On ingestion:
Immediately rinse mouth and then drink 200-300 ml of water, seek medical attention.


 


Most important symptoms and effects, both acute and delayed
Symptoms: Information, i.e. additional information on symptoms and effects may be included in the GHS labeling phrases available in Section 2 and in the Toxicological assessments available in Section 11., Further symptoms are possible


 


Indication of any immediate medical attention and special treatment needed
Treatment: Treat according to symptoms (decontamination, vital functions), no known specific antidote.

Fire-fighting measures

Extinguishing media
Suitable extinguishing media:
water spray, dry powder, foam, carbon dioxide


Special hazards arising from the substance or mixture
toxic gases/vapours
The substances/groups of substances mentioned can be released in case of fire.


Advice for fire-fighters
Special protective equipment:
Wear self-contained breathing apparatus and chemical-protective clothing.


Further information:
Dispose of fire debris and contaminated extinguishing water in accordance with official regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Avoid inhalation. Avoid contact with the skin, eyes and clothing.


 


Environmental precautions
Do not discharge into drains/surface waters/groundwater.


 


Methods and material for containment and cleaning up
For large amounts: Pump off product.
For residues: Pick up with suitable absorbent material (e.g. sand, sawdust, general-purpose binder, kieselguhr).
Clean contaminated floors and objects thoroughly with water and detergents, observing environmental regulations. Collect waste in suitable containers, which can be labeled and sealed. Incinerate or take to a special waste disposal site in accordance with local authority regulations.

Handling and storage

Precautions for safe handling
Ensure thorough ventilation of stores and work areas. Protect against moisture. Protect from air. Refill and handle product only in closed system.


Handle in accordance with good industrial hygiene and safety practice. When using do not eat, drink or smoke. Hands and/or face should be washed before breaks and at the end of the shift.


 


Protection against fire and explosion:
Prevent electrostatic charge - sources of ignition should be kept well clear - fire extinguishers should be kept handy.


 


Conditions for safe storage, including any incompatibilities


Segregate from acids and acid forming substances.


Suitable materials for containers: Carbon steel (Iron), Stainless steel 1.4541, Stainless steel 1.4571, glass
Further information on storage conditions:  Containers should be stored tightly sealed in a dry place.


Storage stability:
Storage temperature: <= 50 °C
Storage duration: 24 Months
From the data on storage duration in this safety data sheet no agreed statement regarding the warrantee of application properties can be deduced.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters


Components with occupational exposure limits









107-15-3: Ethylenediamine



Exposure controls


Personal protective equipment
Respiratory protection:
Respiratory protection in case of vapour/aerosol release. Gas filter for gases/vapours of organic compounds (boiling point >65 °C, e. g. EN 14387 Type A)


Hand protection:
Chemical resistant protective gloves (EN ISO 374-1)
Suitable materials also with prolonged, direct contact (Recommended:  Protective index 6, corresponding > 480 minutes of permeation time according to EN ISO 374-1):
butyl rubber (butyl) - 0.7 mm coating thickness


Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing.


Eye protection:
Tightly fitting safety goggles (cage goggles) (e.g. EN 166) and face shield.


Body protection:
chemical-protection suit (f.e. according to EN 14605)


General safety and hygiene measures
Avoid contact with the skin, eyes and clothing. Avoid inhalation of vapour. Handle in accordance with good industrial hygiene and safety practice. Wearing of closed work clothing is required additionally to the stated personal protection equipment. Take off immediately all contaminated clothing. Store work clothing separately.

Stability and reactivity

Reactivity















Corrosion to metals:



Corrosive effects to metal are not anticipated.



Formation of flammable gases:



Remarks:



Forms no flammable gases in the presence of water.



Possibility of hazardous reactions
Strong exothermic reaction with acids.


Conditions to avoid
Avoid all sources of ignition: heat, sparks, open flame.


Incompatible materials
Substances to avoid:
acids, nitrosating agents


Hazardous decomposition products


Hazardous decomposition products:
Carbon monoxide, Carbon dioxide


nitrogen oxides

Disposal considerations

Waste treatment methods
Incinerate in suitable incineration plant, observing local authority regulations.


A waste code in accordance with the European waste catalog (EWC) cannot be specified, due to dependence on the usage.
The waste code in accordance with the European waste catalog (EWC) must be specified in cooperation with disposal agency/manufacturer/authorities.