Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 25 July 2016 to 12 August 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Version / remarks:
Rev. 6 (2015)
Deviations:
no
GLP compliance:
yes
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: substance does ignite but does not propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the test period.

The flame of the gas burner did ignite the test item pile. The test item melted, burned with a yellow/blue flame and turned into a brown residue. White smoke was observed. After removal of the ignition source, the flame extinguished after 1 second.

Interpretation of results:
other: Not classified as Flammable solid
Remarks:
in accordance with EU CLP (EC no. 1272/2008 and its amendments)
Conclusions:
The substance is not flammable/not readily combustible.
Executive summary:

The substance was not highly flammable/not readily combustible in a GLP-compliant preliminary screening test according to EC A.10 and UN Test N.1.

Description of key information

The substance was determined to be not highly flammable/not readily combustible in a GLP-compliant preliminary screening test according to EC A.10 and UN Test N.1.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

CLP /GHS: not classified as a 'Flammable solid'