Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
Identification: Cyclohexylamine Benzoate
Storage: Stored in a HPLC vial at suitable temperature
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
< 0
Temp.:
20 °C
pH:
7
Remarks on result:
other:
Remarks:
peak observed on diode array detector
Key result
Type:
log Pow
Partition coefficient:
1.22
Temp.:
20 °C
pH:
7
Remarks on result:
other:
Remarks:
peak observed on refractive index detector
Details on results:
One peak was detected using the Diode Array Detector , showing a log Pow of <0. The Refractive Index Detector also detected a peak with a value of log Pow = 1.22.
Conclusions:
A sample of cyclohexylamine benzoate was assessed for its partition coefficient using a HPLC method accoridng to OECD TG 117.
One peak was detected using the Diode Array Detector , showing a log Pow of <0. The Refractive Index Detector also detected a peak with a value of log Pow = 1.22.
Executive summary:

A sample of cyclohexylamine benzoate was assessed for its partition coefficient using a HPLC method accoridng to OECD TG 117.

One peak was detected using the Diode Array Detector , showing a log Pow of <0. The Refractive Index Detector also detected a peak with a value of log Pow = 1.22.

Description of key information

A sample of cyclohexylamine benzoate was assessed for its partition coefficient using a HPLC method accoridng to OECD TG 117.

One peak was detected using the Diode Array Detector , showing a log Pow of <0. The Refractive Index Detector also detected a peak with a value of log Pow = 1.22.

Key value for chemical safety assessment

Log Kow (Log Pow):
1.22
at the temperature of:
20 °C

Additional information