Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Other quality assurance:
other: The audits were carried out according to the standard operating procedures of the Quality Assurance Unit of Jai Research Foundation (JRF) and in compliance with the OECD monograph N° 4, ENV/JM/MONO(99)20 (1999).
Remarks:
.
Type of method:
non-equilibrium method
Flash point apparatus:
Abel apparatus
Specific details on test material used for the study:
Test Item Name TYZOR 9000
Batch/Lot Number 334-300130/000049

Analysed Concentration (Titanium in product as TiO2) (Provided by Sponsor): 23.25%
Date of Manufacture September2017
Date of Expiry September2019

Storage Condition (at JRF):
As per SDS
Storage Container : In original container as supplied by the sponsor
Storage Location : Test Item Control Office, JRF


Key result
Flash point:
ca. 50 °C
Atm. press.:
ca. 760 mm Hg

TABLE 1: Flash Point

Replication

Flash Point (°C)

Observation

R1

50

Bursting sound was heard

R2

50

R3

50

Mean (°C)

50

SD

0.00

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Executive summary:

The flash point of TYZOR 9000 was determined by the non-equilibrium method by using of Abel apparatus .

The bursting sound were heard at 50, 50 and 50 °C in replication R1, R2and R3respectively. Hence, the mean flash point of TYZOR 9000 was 50± 0.0 °C at normal atmospheric pressure (i.e. 760 mm Hg).

Description of key information

The flash point of substance was determined by the non-equilibrium method by using of Abel apparatus .

The mean flash point of substance was 50± 0.0 °C at normal atmospheric pressure (i.e. 760 mm Hg).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
50 °C

Additional information