Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 Jan 2018 - 25 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks:
An equilibrium method was also applied in the main study

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2,2-trifluoro-1-(trifluoromethyl)ethyl methacrylate
EC Number:
221-309-9
EC Name:
2,2,2-trifluoro-1-(trifluoromethyl)ethyl methacrylate
Cas Number:
3063-94-3
Molecular formula:
C7H6F6O2
IUPAC Name:
2,2,2-trifluoro-1-(trifluoromethyl)ethyl methacrylate
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 449935-248
- Expiration date of the lot/batch: 30 March 2018
- Purity test date: Not specified


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: In refrigerator (2-8°C)
- Stability under test conditions: Stable

Results and discussion

Flash point
Key result
Flash point:
22 °C
Atm. press.:
760 mm Hg

Any other information on results incl. tables

Preliminary Test

The estimated flash-point of the test item was 21°C.

Main Study

The results of the main study on the determination of the flash-point of the test item are given in the table below.

The difference between the results obtained with the Test 1 and Test 2 was2°C6°C. From this, it was concluded that the flash-point of the test item is the lowest flash-point obtained.

    
Main Study: Flash-point of the Test Item

Test

Flash-point

[°C]

Lowest flash-point

[°C]

1

22

22

2

22

 

 

Equilibrium Method

The results of the equilibrium method are given in the following tables:

      
Equilibrium Method: Test with 5°C Interval

Test

Expected flash-point

[°C]

Result

1

22

Flash

2

17

Flash

3

12

No flash

 

 
Equilibrium Method: Tests with 1°C Interval

Test

Expected flash-point

[°C]

Result

1

13

No flash

2

14

No flash

3

15

Flash

Applicant's summary and conclusion

Interpretation of results:
Category 2 (highly flammable liquids) based on GHS criteria
Conclusions:
The closed cup method was applied for the determination of the flash-point of 2,2,2-trifluoro-1-(trifluoromethyl)ethyl methacrylate.
The flash-point of the test item was 22°C.
Since the flash-point of the test item was in the range in the range of 23°C  2°C the equilibrium method was applied. The flash-point of the test item obtained with the equilibrium method was 15°C.