Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Not stated in report
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP/Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
yes

Test material

Constituent 1
Test material form:
other: solid
Details on test material:
Purified active substance. Lot# AAP 12536, with purity = 99.7%.

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
> 240 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
ignition on contact with air (not further specified)
Remarks:
corresponding to 'yes' in migrated source record.| Remarks: | Additional remarks: Test material melted and ignited but the flame did not propagate along the test pile.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
ignition on contact with air (not further specified)
Remarks:
corresponding to 'yes' in migrated source record.| Remarks: | Additional remarks: Test material melted and ignited but the flame did not propagate along the test pile.

Any other information on results incl. tables

Kordek 573T industrial microbiocide melted and ignited, but the flame did not propagate along the test pile.

Under the terms of the test method, the full burning rate test was not required because the test substance did not propagate along the test pile.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Kordek 573T industrial microbiocide is not highly flammable.
Executive summary:

Using EU Method A10, Kordek 573T industrial microbiocide was not highly flammable.