Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard OECD test guidelines
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
GLP compliance:
no
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
1.518
Temp.:
25 °C
pH:
8
Remarks on result:
other: logKow was reported to be 1.5175 ± 0.0213
Details on results:
The Partition coefficient (Pow) of the test chemical was determined to be 1.5175 ± 0.0213 at 25°C

Table:

Test substance

 

K

Log k

Log Pow by Generalized Calibration

Graph

Mean of Log Pow ± S.D.

Rt1

0.683

-0.2734

-0.5632

1.5024

1.5175±0.0213

Rt2

0.676

-0.2808

-0.5515

1.5325

Conclusions:
The partition coefficient (n-octanol/water) of test chemical was determined as per the HPLC method (OECD Guideline-117). The Log Pow value was determined to be 1.5175 ± 0.0213 at 25°C.
Executive summary:

The partition Coefficient n-octanol/water of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 117 for testing of Chemicals. A test solution was prepared by accurately measuring 4μL of test chemical and diluted with acetonitrile up to 10 ml. Thus, the test solution concentration was 392 mg/l. The pH of test substance was 8.0. The reference substances were chosen according to estimated Pow range of the test substance and generalized calibration graph was prepared. The reference substances were having Pow value ranging from 0.5 to 4.6. The Log Pow value was determined to be 1.5175 ± 0.0213 dimensionless at 25°C. On the basis of this value, test chemical can be considered to be hydrophilic in nature.

Description of key information

The partition Coefficient n-octanol/water of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 117 for testing of Chemicals. A test solution was prepared by accurately measuring 4μL of test chemical and diluted with acetonitrile up to 10 ml. Thus, the test solution concentration was 392 mg/l. The pH of test substance was 8.0. The reference substances were chosen according to estimated Pow range of the test substance and generalized calibration graph was prepared. The reference substances were having Pow value ranging from 0.5 to 4.6. The Log Pow value was determined to be 1.5175 ± 0.0213 dimensionless at 25°C. On the basis of this value, test chemical can be considered to be hydrophilic in nature.

Key value for chemical safety assessment

Log Kow (Log Pow):
1.517
at the temperature of:
25 °C

Additional information

The partition Coefficient n-octanol/water of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 117 for testing of Chemicals. A test solution was prepared by accurately measuring 4μL of test chemical and diluted with acetonitrile up to 10 ml. Thus, the test solution concentration was 392 mg/l. The pH of test substance was 8.0. The reference substances were chosen according to estimated Pow range of the test substance and generalized calibration graph was prepared. The reference substances were having Pow value ranging from 0.5 to 4.6. The Log Pow value was determined to be 1.5175 ± 0.0213 dimensionless at 25°C. On the basis of this value, test chemical can be considered to be hydrophilic in nature.