Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
Version / remarks:
2002
Qualifier:
according to guideline
Guideline:
ISO No., other: DIN51755
GLP compliance:
not specified
Type of method:
closed cup
Flash point:
26.5 °C
Atm. press.:
1 013 hPa
Conclusions:
The flash point of the substance was measured to be 26.5 °C. The result is considered reliable.
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2003
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D92
GLP compliance:
no
Type of method:
open cup
Flash point:
26 °C
Atm. press.:
1 013 hPa
Conclusions:
The flash point of the test substance was measured to be 26 °C at standard pressure based on an open cup method.
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2003
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Flash point:
19 °C
Atm. press.:
1 013 hPa
Conclusions:
The flash point of the test substance was measured to be 19°C at standard pressure based on a closed cup method.

Description of key information

Flash point (triethoxysilane): 19°C (ISO 2719, closed cup)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
19 °C

Additional information

The flash point of the test substance was measured to be 19°C at standard pressure based on a method equivalent to ISO 2719:2002 Determination of flash point - Pensky-Martens closed cup method. The study was conducted according to a standard guideline and is considered reliable for assessment. This is supported by an additional studies reporting flash point values of 26 -26.5°C.