Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006-01-04 to 2006-01-26
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Qualifier:
according to guideline
Guideline:
DIN 51562 Part 1 (Viscometry - Measurement of kinematic viscosity by means of the Ubbelohde viscometer - Part 1: Viscometer specification and measurement procedure)
GLP compliance:
no
Other quality assurance:
other: ISO 3104
Type of method:
capillary viscometer (static)
Remarks:
Micro-Ubbelohde viscometer according to DIN 51 562
Standard covering the apparatus used:
Water bath and thermostat (Lauda)
Thermostat Type E200
Circulating cooler DL K 10
Calibrated thermometer
Micro-Ubbelohde viscometer
Timing device Schott AVS
Specific details on test material used for the study:
- Name of test material (as cited in study report): 2-Hydroxyethyl methacrylate
- Physical state: liquid
- Analytical purity: 98.9%
- Lot/batch No.: 1035092208
- Stability under test conditions: stable
- Storage condition of test material: between room temperature and 4 °C
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
6.36
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.42
Conclusions:
The kinematic viscosity of 2-hydroxyethyl methacrylate was measured with a micro-Ubbelohde viscometer according to DIN 51 562 at 20°C and 40°C. Kinematic viscosity at was 6.36 mm²/s at 20 °C and  3.42 mm²/s at 40°C.
Executive summary:

The kinematic viscosity of 2-hydroxyethyl methacrylate was measured with a micro-Ubbelohde viscometer according to DIN 51 562 at 20°C and 40°C. Kinematic viscosity at was 6.36 mm²/s at 20 °C and  3.42 mm²/s at 40°C.

Description of key information

The kinematic viscosity of 2-hydroxyethyl methacrylate was measured with a micro-Ubbelohde viscometer according to DIN 51 562 at 20°C and 40°C. Kinematic viscosity was 6.36 mm²/s at 20 °C and  3.42 mm²/s at 40°C.

Key value for chemical safety assessment

Viscosity:
6.36 mm²/s (static)
at the temperature of:
20 °C

Additional information