Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Description of key information

Key value for chemical safety assessment

Skin sensitisation

Endpoint conclusion
Endpoint conclusion:
adverse effect observed (sensitising)
Additional information:

The test substance was assessed for skin sensitisation according to OECD guideline 429. The test item was considered to be a sensitiser under the conditions of the test. Results below:

Treatment group

Concentration

Stimulation Index

Result

Test item

25 % v/v in acetone/olive oil 4:1

1.43

Negative

Test item

50 % v/v in acetone/olive oil 4:1

2.03

Negative

Test item

100 % v/v

5.08

Positive

Positive control

25 % v/v in acetone/olive oil 4:1

7.33

Positive



Migrated from Short description of key information:
The test substance was assessed for skin sensitisation according to OECD guideline 429.

Respiratory sensitisation

Endpoint conclusion
Endpoint conclusion:
no study available

Justification for classification or non-classification

The test substance was assessed for skin sensitisation according to OECD guideline 429. The test item was considered to be a sensitiser under the conditions of the test.