Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 205-459-2 | CAS number: 141-12-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flash point
Administrative data
Link to relevant study record(s)
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 29 July 2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study performed according to EU A.9 guideline, under GLP, without deviation and with certificate of analysis included.
- Reason / purpose for cross-reference:
- reference to other study
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.9 (Flash-Point)
- Deviations:
- not specified
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- 2015-03-05
- Type of method:
- equilibrium method closed cup
- Flash point apparatus:
- Setaflash apparatus
- Flash point:
- 106 °C
- Atm. press.:
- 101.3 kPa
- Remarks on result:
- other: First determination
- Flash point:
- 106 °C
- Atm. press.:
- 101.3 kPa
- Remarks on result:
- other: Second determination
- Key result
- Flash point:
- 106 °C
- Atm. press.:
- ca. 101.3 kPa
- Remarks on result:
- other: Mean of the two determinations
- Conclusions:
- The corrected flash point of NERYL ACETATE is 106.0°C at 101.3 kPa (lowest value of two independent determinations).
- Executive summary:
A study was performed to determine the flash point of the test item NERYL ACETATE. The method followed was designed to be compliant with the Method A.9 of Commission Regulation No. 440/2008, ''Flash Point''.
The flash point of the test item is determined with a closed cup tester, by an equilibrium method called "Small Scale", (commonly known as Setaflash).
The substance is placed into a test cup and heated using a temperature gradient program. Ignition trials are carried out in order to ascertain whether or not the sample flashes at the temperature tested.
A pre-test followed by two determinations were conducted. For the pre-test, a flash point of 106.0°C was observed. This data was used to select the range of temperatures for the following determinations.
Determinations 1 and 2 respectively gave a corrected flash point of 106.0°C at 101.3kPa.
Moreover the flash point of the reference substances Butanol-1 and CRM respects the checking cards limits.
The corrected flash point of the test item was determined to be 106.0°C at 101.3 kPa (lowest value of two independent determinations).
Reference
Results:
Pre-test:
The flash point of the test item was estimated at 106.0°C during the pre-test.
First determination:
The flash point of the test item was estimated at 106.0°C during the first determination.
An automatic correction was applied to the obtained result because the ambient pressure was not 101.3 kPa but 101.6 kPa.
With this correction, the flash point value is still 106.0°C at 101.3 kPa.
Second determination:
The flash point was detected at 106.0°C and the same automatic correction was applied because the ambient pressure was still 101.6 kPa.
With this correction, the flash point value is still 106.0°C at 101.3 kPa.
Description of key information
The flash point was determined with a closed cup tester by Setaflash method.
The flash point of neryl acetate is 106°C.
Neryl acetate is not classified as flammable according to Regulation (EC) No 1272/2008 (CLP) criteria.
Key value for chemical safety assessment
- Flash point at 101 325 Pa:
- 106 °C
Additional information
The flash point of neryl acetate was determined in a study performed according to EU method A.9.
As the results were obtained under GLP without deviation, they were considered as valid and reliable without restriction and used as key value.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.