Administrative data

First-aid measures

Description of first aid measures:

General advice: Remove contaminated clothing immediately and dispose of safely.

If inhaled: Take medical treatment.

In case of skin contact: In case of contact with skin wash off immediately with plenty of water.

In case of eye contact: In case of contact with eyes rinse thoroughly with plenty of water and seek medical advice

If swallowed: When swallowed seek medical aid immediately and show the physician the packaging or the label of the packaging.

Most important symptoms and effects, both acute and delayed

Symptoms: No information available.

Hazards: Danger of Sympathicomimetric effect must be observed.

Indication of any immediate medical attention and special treatment needed

Treatment: Treat symptomatically.

Fire-fighting measures

Extinguishing media:

Suitable extinguishing media:Water. water mist Foam. Dry powder. Carbon dioxide.

Special hazards arising from the substance or mixture:In case of fires, hazardous combustion gases are formed: Carbon monoxide (CO). Carbon dioxide (CO2) Nitrogen oxides (NOx)

Advice for firefighters:

Special protective equipment: Use self-contained breathing apparatus.

Further information: Fire residues and contaminated firefighting water must be disposed of in accordance with the local regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Avoid dust formation. Use personal protective clothing. If ventilation insufficient, use a respiratory protection apparatus.

Environmental precautions:

Do not allow to enter drains or waterways.

Methods and materials for containment and cleaning up: General advice: Take up mechanically

When picked up, treat material as prescribed under heading "Disposal".

Reference to other sections:

Information regarding Safe handling, see chapter 7. Information regarding personal protective measures see, chapter 8. Information regarding Waste Disposal, see chapter 13.

Handling and storage

Precautions for safe handling:

Advice on safe handling (industrial scale):

Avoid the formation and deposition of dust. Provide exhaust ventilation if dust is formed. Take precautionary measures against electrostatic loading.

Advice on protection against fire and explosion: Take precautionary measures against electrostatic loading. Observe the general rules of industrial fire protection

Conditions for safe storage, including any incompatibilities:

Requirements for storage rooms and vessels: Keep only in the original container

Advice on common storage: Do not store with chemicals Keep away from chemicals as it is a pharmaceutical substance

Further information on storage conditions : Keep container tightly closed and dry

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN2811
Shippingopen allclose all
Labels:
6.1
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN2811
Shipping information
Proper shipping name and description:
TOXIC SOLID, ORGANIC, N.O.S.
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN2811
Shipping information
Proper shipping name and description:
TOXIC SOLID, ORGANIC, N.O.S.
Labels:
6.1
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Personal protection equipment

(IMPORTANT: to be adapted following the workplace risk assessment.)

General protective measures:

Do not inhale dust. Contact with eyes and skin must be avoided A workplace risk assessment must be carried out in order to determine the correct engineering control measures and personal protective equipment. Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier.

Industrial workplace

Respiratory protection:

Particle filter half mask, filter P3. Powered Air-purifying respirator (PAPR) - mounted airhat

Hand protection:

Nitrile rubber gloves. Glove material : Dermatril® (KCL) Layer thickness : 0,11 mm Break through time: > 480 min

Glove material : Camatril® (KCL) Layer thickness : 0,5 mm Break through time: > 480 min

The protective gloves to be used must comply with the specifications of EC directive 89/686/EEC and the resultant standart EN374. This recommandation applies only to the product stated in this safety data sheet and supplied by us as well as to the purpose specified by us. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves.

Eye/face protection: Safety glasses with side protection shield.

Body Protection :Protective clothing

Additional advice on system design: Use under strictly controlled conditions.

Hygiene measures: Wash hands before breaks and after work. Do not eat or drink during work time. Keep away from foodstuffs and beverages.

Laboratory

Respiratory protection: Handling in a fume cupboard.

Hand protection:

Nitrile rubber gloves.

Layer thickness: > 0.11 mm.

Breakthrough time: > 480 min.

Eye/face protection: Safety glasses with side protection shield.

Body Protection: Dedicated working clothes.

Hygiene measures: Wash hands before breaks and at the end of workday.

Stability and reactivity

Reactivity: No decomposition if used as directed.

Chemical stability: No decomposition if stored normally.

Possibility of hazardous reactions : Accumulation of fine dust may entail the risk of a dust explosion in the presence of air.

Conditions to avoid:No data available.

Incompatible materials: None known.

Hazardous decomposition products: No hazardous decomposition products known.

Disposal considerations

Waste treatment methods:

Product:

In accordance with regulations for special waste, must be taken to an authorised special waste incineration plant.

Uncleaned packaging: Packaging that cannot be cleaned should be disposed off as product waste