Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
8,9,10-trinorborna-2,5-diene
EC Number:
204-472-0
EC Name:
8,9,10-trinorborna-2,5-diene
Cas Number:
121-46-0
Molecular formula:
C7H8
IUPAC Name:
bicyclo[2.2.1]hepta-2,5-diene
Specific details on test material used for the study:
Batch No. 10005609
Purity > 99.8%
Stability under storage conditions: Stable
Manufactured date 16/08/2017
Expiry date 16/08/2018

SOURCE OF TEST MATERIAL
- Source and batch number of test material: Air Liquide Electronics Materials (ALEM), Batch No. 10005611
- Purity > 99.8%

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Container closed when not in use. Kept in fireproof place. Stored in a well-ventilated place at ambient temperature.
- Stability of the test material under test conditions and during storage: stable

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
No treatment of test material prior to testing.

Results and discussion

Flash point
Key result
Flash point:
<= 25 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Conclusions:
The flash point of the test item was determined to be ≤ 25.0°C at 101.3 kPa.
Executive summary:

A study was performed to determine the flash point of the test item REACTION MASS OF BICYCLO 2.2.1-HEPTA-2.5-DIENE-BCHD.


The flash point of the test item is determined with a closed cup tester, by an equilibrium method called “Small Scale” (commonly known as Setaflash).
The substance is placed into a test cup and heated using a temperature gradient program. Ignition trials are carried out in order to ascertain whether or not the sample flashes at the temperature tested.


A pre-test was conducted and measurements were stopped as the test item ignited when the ignitor dipped into the test cup even if no flash was detected by the apparatus.
As the apparatus cannot perform measurements at temperatures lower than the ambient temperature, the flash point is considered to be less or equal to the apparatus temperature at the beginning of the test (25°C).
The flash point of the reference substances Butanol-1 and CRM respects the checking cards limits.