Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard OECD test guidelines.
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
The flash point determination of Geranyl phenylacetate (CAS No. 102-22-7 ) was done, via closed cup method using Pensky-Martens Flash Point Aparatus.
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Name of the test chemical: (2E)-3,7-dimethylocta-2,6-dien-1-yl 2-phenylacetate/ Geranyl phenylacetate
Molecular formula: C18H24O2
Molecular weight: 272.3856 g/mol
Smiles Notation: c1(CC(OC\C=C(\CC\C=C(\C)C)C)=O)ccccc1
InChI: 1S/C18H24O2/c1-15(2)8-7-9-16(3)12-13-20-18(19)14-17-10-5-4-6-11-17/h4-6,8,10-12H,7,9,13-14H2,1-3H3/b16-12+
Substance Type: Organic
Physical State: Liquid (Colorless)
Key result
Flash point:
101.6 °C
Atm. press.:
970 hPa
Remarks on result:
other: no other details mentioned

TEST DESCRIPTION AND RESULT

Method Details

 

Observations

Remarks if,

any

Method

Closed cup method

 

 

Principle of Flash point test

The flash point of a flammable

liquid is the lowest temperature at

which there will be enough

flammable vapor to ignite when an

ignition source is applied.

 

Type of method

·        

 

Flash point apparatus

·        

·        

Pensky-Martens flash point apparatus

Quantity of chemical used

g/ml

5 ml

Ignition source

Gas lighter/flame

Gas lighter

Atmospheric pressure

hPa

970.0hPa

meanFlash point

(RESULT)

°C

101.6°C

Conclusions:
The mean flash point of Geranyl phenylacetate (CAS No. 102-22-7) is 101.6°C at 970.0 hPa.
Executive summary:

The flash point determination of Geranyl phenylacetate (CAS No. 102-22-7) was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was found to be 101.6°C at 970.0 hPa.

Description of key information

The mean flash point of Geranyl phenylacetate (CAS No. 102-22-7) is 101.6°C at 970.0 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
101.6 °C

Additional information

The flash point determination of Geranyl phenylacetate (CAS No. 102-22-7) was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was found to be 101.6°C at 970.0 hPa.