Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising properties
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05.02.2013 - 13.02.2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
other: as mention below
Principles of method if other than guideline:
Redox titrations are based on a reduction-oxidation reaction between an oxidizing agent and a reducing agent. A potentiometer or a redox indicator is usually used to determine the endpoint of the titration. In permanganometry a slight faint persisting pink color signals the endpoint of the titration because of the color of the excess oxidizing agent potassium permanganate
GLP compliance:
no
Specific details on test material used for the study:
- Name of test material (as cited in study report): 2-amino-4-nitrophenol
- Molecular Formula: C6H6N2O3
- Molecular Weight: 154.125 g/mol
- SMILES Notation: C1=CC(=C(C=C1[N+](=O)[O-])N)O
- InChI: 1S/C6H6N2O3/c7-5-3-4(8(10)11)1-2-6(5)9/h1-3,9H,7H2
- Substance type: Organic
- Physical state: solid
Sample tested:
other: not specified (migrated information) Redox Tritration
Parameter:
other: Redox Tritration
Result:
279.73 other: ml/100g
Remarks on result:
other: No other detail available
Key result
Sample tested:
other: not specified (migrated information) Redox Tritration
Parameter:
other: Redox Tritration
Result:
279.73 other: ml/100g
Remarks on result:
other: No other detail available
Interpretation of results:
other: mild oxidising property
Conclusions:
2-amino-4-nitrophenol was determine to have mild oxidising property since 279.73 ml of KMnO4 was required for getting the end point of the redox titration for 100 g of 2-amino-4-nitrophenol.
Executive summary:

2-amino-4-nitrophenol was determine to have mild oxidising property since 279.73 ml of KMnO4 was required for getting the end point of the redox titration for 100 g of 2-amino-4-nitrophenol.

Description of key information

2-amino-4-nitrophenol was determine to have mild oxidising property since 279.73 ml of KMnO4 was required for getting the end point of the redox titration for 100 g of 2-amino-4-nitrophenol.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

2-amino-4-nitrophenol was determine to have mild oxidising property since 279.73 ml of KMnO4 was required for getting the end point of the redox titration for 100 g of 2-amino-4-nitrophenol.

Justification for classification or non-classification

2-amino-4-nitrophenol was determine to have mild oxidising property since 279.73 ml of KMnO4 was required for getting the end point of the redox titration for 100 g of 2-amino-4-nitrophenol.