Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
Identification: Isobutyl isobutyrate
Appearance/Physical state: Clear colorless liquid
Batch: TXTXOL
Purity: 99.998 %
Expiry date: 06 February 2018
Storage conditions: Room temperature in the dark
Key result
Flash point:
40 °C
Atm. press.:
100 kPa
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
40 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008
Executive summary:

The determination was carried out using a closed cup flash point tester using a procedure designed to be compatible with Method A.9. An aliquot (2 mL) of the test item was transferred to the sample cup of the Setaflash 30000-0 tester. The sample was heated and allowed to equilibrate at the set temperature. The test flame was introduced into the sample cup for approximately 2½ seconds by sliding the cup shutter open. Observations were made for ignition of the vapor. If no ignition occurred, the temperature was increased and the test flame re-introduced. This was repeated until the lowest reproducible temperature at which a flash occurred, using a fresh sample, was determined. The flash point of the test item has been determined to be 40 ± 2 °C at atmospheric pressure of 100.9 kPa.

Description of key information

The determination was carried out using a closed cup flash point tester using a procedure designed to be compatible with Method A.9. An aliquot (2 mL) of the test item was transferred to the sample cup of the Setaflash 30000-0 tester. The sample was heated and allowed to equilibrate at the set temperature. The test flame was introduced into the sample cup for approximately 2½ seconds by sliding the cup shutter open. Observations were made for ignition of the vapor. If no ignition occurred, the temperature was increased and the test flame re-introduced. This was repeated until the lowest reproducible temperature at which a flash occurred, using a fresh sample, was determined. The flash point of the test item has been determined to be 40 ± 2 °C at atmospheric pressure of 100.9 kPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
40 °C

Additional information