Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 April 2010 - 15 November 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study with GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.12 (Flammability (Contact with Water))
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.13 (Pyrophoric Properties of Solids and Liquids)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
4-amino-2-methylpyrimidine-5-methylamine
EC Number:
202-384-7
EC Name:
4-amino-2-methylpyrimidine-5-methylamine
Cas Number:
95-02-3
Molecular formula:
C6H10N4
IUPAC Name:
5-(aminomethyl)-2-methylpyrimidin-4-amine
Details on test material:
- Name of test material (as cited in study report): Grewe-diamin
- Physical state: solid

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
0 s
Remarks on result:
other: The test substance ignited and melted. After removing the gas burner the flame extinguished immediately
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

 Flammability

The test substance ignited and melted. After removing the gas burner the flame extinguished immediately.

The test substance did not burn over a length of 200 mm within 4 minutes. Therefore the full test programme (main test) was not carried out and the test substance is not classified as "highly flammable", according to the guideline.

The loss on drying of the test substance is 2.5 % (dried at 100 °C for 4 hours).

 

Flammability in Contact with Water

The practical experience of the sponsor and the test facility shows that no gases are developed, when the test substance is in contact with water.
The test substance is therefore regarded as not being flammable in contact with water.

 

Pyrophoricity

The test was not performed experimentally because practical experience exists at the sponsor and the test facility, e.g. when handling small amounts of the test substance repeatedly in air during testing.

The test substance is therefore regarded as not being pyrophoric.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Flammability:
The test substance ignited and melted. After removing the gas burner the flame extinguished immediately.
The test substance did not burn over a length of 200 mm within 4 minutes. Therefore the full test programme (main test) was not carried out and the
test substance is not classified as "highly flammable", according to the guideline.
Flammability in Contact with Water
The test substance is regarded as not being flammable in contact with water.
Pyrophoricity
The test substance is regarded as not being pyrophoric.


Executive summary:

 Flammability

The test substance ignited and melted. After removing the gas burner the flame extinguished immediately.

The test substance did not burn over a length of 200 mm within 4 minutes. Therefore the full test programme (main test) was not carried out and the test substance is not classified as "highly flammable", according to the guideline.

The loss on drying of the test substance is 2.5 % (dried at 100 °C for 4 hours).

 

Flammability in Contact with Water

The practical experience of the sponsor and the test facility shows that no gases are developed, when the test substance is in contact with water.
The test substance is therefore regarded as not being flammable in contact with water.

 

Pyrophoricity

The test was not performed experimentally because practical experience exists at the sponsor and the test facility, e.g. when handling small amounts of the test substance repeatedly in air during testing.

The test substance is therefore regarded as not being pyrophoric.

.