Registration Dossier

Administrative data

First-aid measures

Eye contact
- rinse immediately with tap water for at least 20 minutes - open eyelids forcibly
- consult a physician

Skin contact
- remove immediately contaminated clothes, wash affected skin with water and soap
- do not use any solvents

Inhalation
- remove the casualty to fresh air and keep him/her calm
- get medical treatment

Fire-fighting measures

Suitable extinguishing agents :
Water spray jet, dry powder, foam, carbon dioxide.
Adapt extinguishing media to surrounding fire conditions.

Special hazards arising from the substance :
substance is hazardous for water : contain fire-fighting wastewater

Advice for firefighters :
Precipitate gases/vapours/mists with water spray

Accidental release measures

Personal precautions, protective equipment and emergency procedures
- avoid exposure

Environmental protection
- do not allow to enter drains or waterways
- if the substance reaches waters or the sewer system, inform the competent authority

Methods for cleaning up
- collect solids (avoid dust formation) and hand over to waste removal

Handling and storage

Precautions for safe handling :
Processing in closed systems, if possible superposed by inert gas (e.g. nitrogen).
Low probability of ignition : ground plant, avoid effective ignition sources.

Conditions for safe storage, including any incompatibilities :
storage conditions : room temperature
protected from light and humidity

Packaging material : tightly closing

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

respiratory protection :
In case of open handling or accidental release : particle mask or respirator with independent air supply.

Hand protection :
Protective gloves (e.g. made of neoprene, nitrile or butyl rubber)

Eye Protection :
safety glasses

Stability and reactivity

Reactivity : no information available

Chemical stability : autocatalytic decomposition suspected

Possibility of hazardous reactions : no information available

Conditions to avoid :
Temperatures above 160°C
Humidity
Light

Incompatible materials : no information available

hazardous decomposition products : no information available

Disposal considerations

Waste treatment methods recommendation :
Observe local/nationaql regulations regarding waste disposal.
Incinerate in qualified installation with flue gas scrubbing.