Registration Dossier

Administrative data

Endpoint:
phototransformation in air
Type of information:
(Q)SAR
Adequacy of study:
other information
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: Original reference not yet available
Justification for type of information:
QSAR prediction: migrated from IUCLID 5.6

Data source

Reference
Reference Type:
secondary source
Title:
unpublished study (1995) - SU Umwelt Departement|(27/04/1995)
Author:
Hoechst
Bibliographic source:
IUCLID4 Dataset

Materials and methods

Principles of method if other than guideline:
Method: other (calculated): EPiWiN, Estimation Program, Syracuse Research Corporation, Syracuse, NY 13210

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent

Study design

Details on test conditions:
Sensitiser (for indirect photolysis): OH
Sensitiser concentration: 500000 molecule/cm³

Results and discussion

% Degradation
% Degr.:
ca. 50
Sampling time:
36 d
Test condition:
indirect photolysis

Any other information on results incl. tables

Rate constant (for indirect photolysis): = 0.0000000000004451 cm³/(molecule*sec)

Applicant's summary and conclusion