Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 May - 23 june 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ISO 13320-1:1999, Particle size analysis - Laser diffraction methods
Deviations:
no
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
51.157 µm
Key result
Percentile:
D10
Mean:
< 6.913 µm
St. dev.:
0.203
Key result
Percentile:
D50
Mean:
< 41.494 µm
St. dev.:
5.97
Key result
Percentile:
D90
Mean:
< 239.29 µm
St. dev.:
2.98

15.39% by volume of sample was seen to be < 10um.

Conclusions:
A Mass Median Aerodynamic Diameter of the test substance is 51.157 x 10^-3 mm

Description of key information

A Mass Median Aerodynamic Diameter of the test substance is 51.157 x 10^-3 mm

Additional information