Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report Date:
2019

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: isothermal thermogravimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressure
Key result
Test no.:
#1
Temp.:
ca. 20 °C
Vapour pressure:
ca. 0 Pa

Applicant's summary and conclusion

Executive summary:

The vapour pressure test was performed according to the OECD Guideline 104 (Vapour Pressure Curve), isothermal thermogravimetrical effusion method.

A value of the vapour pressure of the test item was determined using the data obtained between 170 °C and 200 °C. The vapour pressure of the test item was estimated to be 4.15 x 10-5 Pa at 20 °C.