First-aid measures

Description of first aid measures

Inhalation:

Remove person to fresh air.  If you feel unwell, get medical attention.

Skin Contact:

Immediately wash with soap and water.  Remove contaminated clothing and wash before reuse.  If signs/symptoms develop, get medical attention.

Eye Contact:

No need for first aid is anticipated.

If Swallowed:

Rinse mouth.  If you feel unwell, get medical attention.

Indication of any immediate medical attention and special treatment required

Not applicable

Fire-fighting measures

1. Extinguishing media

In case of fire: Use a fire fighting agent suitable for ordinary combustible material such as water or foam to extinguish.

2. Special hazards arising from the substance or mixture

None inherent in this product.

Hazardous Decomposition or By-Products

Substance                                      Condition

Carbon monoxide           During Combustion

Carbon dioxide           During Combustion

Irritant Vapors or Gases           During Combustion

3. Advice for fire-fighters

Wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the head.

Accidental release measures

1. Personal precautions, protective equipment and emergency procedures

Evacuate area.  Ventilate the area with fresh air.  For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.  

2. Environmental precautions

Avoid release to the environment.

3. Methods and material for containment and cleaning up

Collect as much of the spilled material as possible.  Place in a closed container approved for transportation by appropriate authorities.  Clean up residue.  Seal the container.  Dispose of collected material as soon as possible in accordance with applicable local/regional/national/international regulations.

Handling and storage

1. Precautions for safe handling

Do not handle until all safety precautions have been read and understood.  Do not breathe dust/fume/gas/mist/vapors/spray.  Do not get in eyes, on skin, or on clothing.  Do not eat, drink or smoke when using this product.  Wash thoroughly after handling.  Contaminated work clothing should not be allowed out of the workplace.  Wash contaminated clothing before reuse.  Avoid contact with oxidizing agents (eg. chlorine, chromic acid etc.)  Use personal protective equipment (gloves, respirators, etc.) as required.

2. Conditions for safe storage including any incompatibilities

Store away from acids.  Store away from strong bases.  Store away from oxidizing agents.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

1. Engineering controls

Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment.

Personal protective equipment (PPE)

Eye/face protection

None required.

Skin/hand protection

Select and use gloves and/or protective clothing approved to relevant local standards to prevent skin contact based on the results of an exposure assessment. Selection should be based on use factors such as exposure levels, concentration of the substance or mixture, frequency and duration, physical challenges such as temperature extremes, and other use conditions. Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible gloves/protective clothing.  Note: Nitrile gloves may be worn over polymer laminate gloves to improve dexterity.

Gloves made from the following material(s) are recommended:

Material       Thickness (mm)       Breakthrough Time

Polymer laminate       No data available       No data available

Applicable norms/standards

Use gloves tested to EN 374

If this product is used in a manner that presents a higher potential for exposure (eg. spraying, high splash potential etc.), then use of protective coveralls may be necessary.  Select and use body protection to prevent contact based on the results of an exposure assessment.  The following protective clothing material(s) are recommended: Apron - polymer laminate

Respiratory protection

An exposure assessment may be needed to decide if a respirator is required.  If a respirator is needed, use respirators as part of a full respiratory protection program.  Based on the results of the exposure assessment, select from the following respirator type(s) to reduce inhalation exposure:

Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates

For questions about suitability for a specific application, consult with your respirator manufacturer.

Applicable norms/standards

Use a respirator conforming to EN 140 or EN 136: filter types A & P

Stability and reactivity

1. Reactivity

This material may be reactive with certain agents under certain conditions - see the remaining headings in this section.

2. Chemical stability

Stable.  

 

3. Possibility of hazardous reactions

Hazardous polymerization will not occur.  

4. Conditions to avoid

Not determined

5. Incompatible materials

Strong bases

6. Hazardous decomposition products

None known.       

Disposal considerations

Dispose of contents/ container in accordance with the local/regional/national/international regulations.

Dispose of waste product in a permitted industrial waste facility. As a disposal alternative, incinerate in a permitted waste incineration facility. Proper destruction may require the use of additional fuel during incineration processes. Empty drums/barrels/containers used for transporting and handling hazardous chemicals (chemical substances/mixtures/preparations classified as Hazardous as per  applicable regulations) shall be considered, stored, treated & disposed of as hazardous wastes unless otherwise defined by applicable waste regulations. Consult with the respective regulating authorities to determine the available treatment and disposal facilities.