Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2005-10-17 to 2005-10-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Specific details on test material used for the study:
- Batch n°: 00467090 (charge 05C0836)
- Expiration date: 04 May 2006
- Purity: 99.9%
- Storage condition of test material: at room temperature at about 20°C
Key result
Remarks on result:
no self-ignition observed up to the melting point

Using a linear increase in temperature of about 0.5°C/min, TIC2782 (T002907) showed no exothermic reaction. T002907 has a melting point of about 119.2°C (as determined in RCC study A28631). As the above-mentioned guideline only applies to solids, the temperature range between 119.2°C and 400°C is not relevant for the present test item. At the end of the measurement T002907 had evaporated.

Conclusions:
Based on the results of the EC A.16 test performed, the test item showed no self-ignition up to the melting point.

Description of key information

Based on the results of a GLP study performed according to the EC A.16 method (Weissenfeld M, 2006), the test item showed no self-ignition up to the melting point.

Key value for chemical safety assessment

Additional information