Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 27th, 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Version / remarks:
2015
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Preliminary test

The test item did not ignite at room temperature using a flame as ignition source being applied for at least 2 minutes.

Main test

In the preliminary test the test item could not be ignited by a flame. Thus, the performance of the main test was not necessary.

Final results

The test item could not be ignited applying a flame as ignition source for at least 2 minutes.

Interpretation of results:
other: not classified according to the CLP Regulation (EC 1272/2008)
Conclusions:
The substance is not a flammable solid.
Executive summary:

The substance was tested for flammability according to UN Test N.1.

Test item could not be ignited applying a flame as ignition source for at least 2 minutes.

The substance has not to be classified as flammable solid according to the CLP Regulation (EC 1272/2008).

Description of key information

Not flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

UN Test N.1.

Based on results in the preliminary test, no main test was run. The main test has to be performed in case test item burns over a distance of 200 mm within 2 minutes (20 minutes in case of metal dusts). Otherwise test item is not considered as flammable solid.

Justification for classification or non-classification

The test item could not be ignited applying a flame as ignition source for at least 2 minutes.

Accordingly, the product has not to be classified as flammable solid according to CLP Regulation (EC 1272/2008) Annex 1: 2.7.