Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-05-09 to 2017-06-15
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
(4-amino-1-hydroxy-1-phosphonobutyl)phosphonic acid hydrate
EC Number:
680-378-7
Cas Number:
138624-11-0
Molecular formula:
C4H15NO8P2
IUPAC Name:
(4-amino-1-hydroxy-1-phosphonobutyl)phosphonic acid hydrate
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Sponsor and 610-GTH
- Expiration date of the lot/batch: 31 March 2019
- Purity test date: 2016-04-16

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature protected from light

Results and discussion

Mass median aerodynamic diameter:
ca. 523.649 µm
Geometric standard deviation:
ca. 6.97
Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
ca. 209.301 µm
St. dev.:
3.992
Key result
Percentile:
D50
Mean:
ca. 396.977 µm
St. dev.:
5.284
Key result
Percentile:
D90
Mean:
ca. 672.746 µm
St. dev.:
6.692

Applicant's summary and conclusion

Conclusions:
This study validly assesed the particle size distribution of the test substance.