Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
non flammable liquid
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 February 2016 to 01 December 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Purity: 95.4% w/w
Batch: L002
Physical State / Appearance: Pale yellow liquid
Expiry Date: 31 December 2016
Storage Conditions: Room temperature in the dark
Key result
Flash point:
150 °C
Atm. press.:
1 010 mBar
Interpretation of results:
GHS criteria not met
Remarks:
Not classified under CLP regulation
Conclusions:
The flash point of the test item was found to be 150°C.

Description of key information

The flash point of the test item was found to be 150°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
150 °C

Additional information