Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: non-GLP study sufficient for purpose here
Cross-referenceopen allclose all
Reason / purpose:
reference to same study
Reason / purpose:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ASTM D445
Deviations:
no
Principles of method if other than guideline:
None
GLP compliance:
no
Remarks:
GLP study not necessary here
Type of method:
capillary viscometer (static)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Type:
Constituent
Details on test material:
- AS 650
- Expiration date: December 31, 2011

Results and discussion

Viscosityopen allclose all
Temp.:
other: 100.0°C
Parameter:
other: cSt
Value:
ca. 40.25
Remarks on result:
other: Viscosity reported in centistokes
Temp.:
40°C
Parameter:
other: Cst
Value:
ca. 1 404
Remarks on result:
other: Viscosity reported in centistokes

Any other information on results incl. tables

None

Applicant's summary and conclusion

Conclusions:
Viscosity reported in cSt: 40.25 at 100 deg. C
Viscosity reported in cSt: 1404 at 40 deg. C
Executive summary:

40.2cSt @100 deg C

1404 cSt @40 deg C