Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: non-GLP study sufficient for purpose here.
Cross-referenceopen allclose all
Reason / purpose:
reference to same study
Reason / purpose:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002. Remark: ASTM D93
Deviations:
no
Principles of method if other than guideline:
None applicable
GLP compliance:
no
Remarks:
GLP not hecessary here
Type of method:
equilibrium method closed cup
Remarks:
Pensky-Martens Closed Cup Tester

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Type:
Constituent
Details on test material:
- C79447
- Expiration date: December 31, 2011

Results and discussion

Flash point
Flash point:
ca. 141 °C
Atm. press.:
ca. 738 mm Hg
Remarks on result:
other: Done on same day as other tests for AS 650 at Southwest RI.

Any other information on results incl. tables

None

Applicant's summary and conclusion

Conclusions:
The test was performed in accordance with the procedure and witin the linear range of the calibration.
Executive summary:

Flashpoint of 141 degree centigrade.