Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Oxidising properties were determined by the Oxidising properties Method according to EU Method A.17.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
1-Amino-1-cyclopropanecarbonitrile hydrochloride
EC Number:
629-718-8
Cas Number:
127946-77-4
Molecular formula:
C4H7N2Cl
IUPAC Name:
1-Amino-1-cyclopropanecarbonitrile hydrochloride
Constituent 2
Reference substance name:
1-aminocyclopropane-1-carbonitrile hydrochloride
IUPAC Name:
1-aminocyclopropane-1-carbonitrile hydrochloride

Study design

Contact with:
powdered cellulose
Duration of test (contact time):
>= 56.34 - 111.22 s

Results and discussion

Test results (Oxidising solids)open allclose all
Sample tested:
reference mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
3.27 other: mm/s (migrated information)
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
3.02 other: mm/s (migrated information)
Remarks on result:
other: The mixture with 10% test substance 1-aminocyclopropane-1-carbonitrile hydrochloride shows the highest burning rate.

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
The maximum burning rate of the test substance was determined to be 3.02mm/s and the maximum burning rate of the reference substance was
determined to be 3.27mm/s. Therefore the test substance is considered to have no oxidising properties.