EC number: 268-069-1 | CAS number: 68002-54-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Density
Administrative data
Link to relevant study record(s)
Description of key information
Under the conditions of this study, the density of the test material was determined to be 990 kg/m³ at 20.0 ± 0.5 °C. The relative density was determined to be 0.990.
Key value for chemical safety assessment
- Relative density at 20C:
- 0.99
Additional information
The key study was conducted in line with GLP and the standardised guidelines OECD 109 and EU Method A.3. It was assigned a reliability score of 1 in accordance with the criteria detailed by Klimisch (1997).
The density of the test material was investigated using a gas comparison pycnometer
Due to the test material’s viscous and paste-like nature, it was considered that the usual pycnometer method for liquids would be very difficult. Therefore, it was decided to transfer the test item to a glass vessel at ambient temperature and which could fit inside the sample cell of a gas comparison pycnometer.
The pre-weighed glass vessel was placed in the sample cell of the pycnometer and the pressure readings taken after pressurising the reference cell of known volume and then after switching to the sample cell of known volume, calculating the volume of the vessel.
The test material was transferred to the glass vessel until approximately half full; this was cooled to 20 °C prior to being weighed. This was placed in the sample cell and the measurements performed.
Under the conditions of this study, the density of the test material was determined to be 990 kg/m³ at 20.0 ± 0.5 °C. The relative density was determined to be 0.990.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.