Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

General advice

Pay attention to self-protection.

Remove victims from hazardous area. Immediately remove soiled or soaked clothing and remove it to a safe distance. Keep victim warm, in a stabilized position and covered.

Do not leave victims unattended.

If the casualty is unconscious: Place the victim in the recovery position.

Inhalation

Inhalation is possible if aerosols, mists, dusts, or smoke form.

Move victims into fresh air.

With labored breathing: Provide with oxygen. Consult a doctor.

If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.

Skin contact

Wash off affected area immediately with plenty of water for at least 15 minutes.

If symptoms persist, consult a physician for treatment.

Eye contact

With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.

In case of persistent discomfort: Consult an ophthalmologist.

Ingestion

Rinse out mouth.

Immediately give large quantities of water to drink.

Consult a physician immediately.

Notes to physician

This substance does not have any noteworthy noxious potential. Damage to health is thus not expected.

Fire-fighting measures

Suitable extinguishing media

Water spray, foam, CO2, dry powder.

Extinguishing media which must not be used for safety reasons

high volume water jet

Specific hazards during fire fighting

Hazardous fumes in fires, specific to the product:

Carbon monoxide

hydrochloric acid

Under certain fire conditions, traces of other toxic products may occur.

Formation of flammable or explosive vapour/air mixtures possible.

Special protective equipment for fire-fighters

Wear suitable protective clothing.

In the event of fire, wear self-contained breathing apparatus.

Further information

Water used to extinguish fire should not enter drainage systems, soil, or stretches of water Ensure there are sufficient retaining facilities for water used to extinguish fire. Contaminated fire-extinguishing water must be disposed of in accordance with the regulations issued by the appropriate local authorities.

Fire residues should be disposed of in accordance with the regulations.

Accidental release measures

Personal precautions

Ensure sufficient ventilation.

Wear suitable protective clothing.

Wear personal protective equipment

Keep unauthorized persons away.

Environmental precautions

Do not allow substance to enter soil, bodies of water or sewage canals.

Avoid penetration into drainage system or in rooms situated at a lower level because of danger of explosion.

Methods for cleaning up

Take up mechanically or with an absorbent material.

Handling and storage

Handling

Safe handling advice

Use permissible in closed systems only. Handle and transfer product in closed systems only (gas displacement device).

Ensure that apparatus and pipelines are free from leaks. Do not ventilate into the open.

Suitable loading and unloading device required.

Advice on protection against fire and explosion

Take precautionary measures against static charges, keep away from sources of ignition.

Storage

Keep container tightly closed.

Protect from moisture.

Unsuitable materials       light metals, copper, brass

German storage class

10 - Combustible liquids

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3082
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (1-chloro octane)
Environmentally Hazardous
Chemical name:
1-chloro octane
Language:
English
Labels:
9
Special provisions / remarks
Special provisions:
Tunnel Restriction Code (ADR): (E)

Inland waterway transport (UN RTDG/ADN(R))

UN number:
3082
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (1-chloro octane)
Environmentally Hazardous
Chemical name:
1-chloro octane
Language:
English
Labels:
9
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
3082
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (1-chloro octane)
Marine pollutant
Chemical name:
1-chloro octane
Labels:
9
Marine pollutant
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
3082
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, n.o.s. (1-chloro octane)
Environmentally Hazardous
Chemical name:
1-chloro octane
Labels:
9
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
Loading instructions/Remarks
IATA_C: ERG-Code 9L
IATA_P: ERG-Code 9L
IMDG: IMDG Code segregation group 10 - Liquid halogenated hydrocarbons

Combination traffic :
Labelling of containers / shipping units following main product run as per sea or air transport regulations.

Exposure controls / personal protection

Components with workplace control parameters

none

Engineering measures

Refill and handle product only in closed system.

Leak detection recommended

Do not add wastewater to a biological wastewater treatment plant

Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.

All precautionary measures indicated have to be observed

Personal protective equipment

Respiratory protection

when vapours or aerosols occur

use respiratory equipment with suitable filter or wear a self contained respiratory apparatus

Suitable filter: A, code colour brown

Note time limit for wearing respiratory protective equipment

Hand protection

Accidental release measures

Glove material       Fluorinated rubber (Vitoject), for example, Vitoject (890), Kächele-Cama Latex GmbH (KCL), Germany

Material thickness       0,7 mm

Method              DIN EN 374

Glove material       Nitrile, for example, Camatril (730), Kächele-Cama Latex GmbH (KCL), Germany

Material thickness       0,4 mm

Method              DIN EN 374

Eye protection

safety glasses with side-shields conforming to EN166

close-fitting protective goggles (e.g. closed goggles) recommended

Skin and body protection

Use protective clothing / face shield if necessary.

Hygiene measures

Do not inhale vapours / aerosols.

Avoid contact with skin.

In case of skin contact

Wash off with plenty of water and soap.

No eating, drinking, smoking, or snuffing tobacco at work. Wash face and/or hands before break and end of work.

Take off clothing and shoes contaminated with product. Clean before reuse.

Protective measures

All precautionary measures indicated have to be observed.

Risk assessment and risk monitoring of all work places required.

Health, Safety and Emergency Management System recommended.

Regular safety training is a must.

Written approval necessary in case of non-routine jobs, e.g. maintenance activities.

Stability and reactivity

Hazardous decomposition products

Decomposition products in combustion, chemical or thermal decomposition

hydrogen chloride, hydrochloric acid, Formation of flammable or explosive vapour/air mixtures possible.

Thermal decomposition

Distills without decomposition at atmospheric pressure.

Hazardous reactions

no

Disposal considerations

Product

Strictly controlled conditions during disposal or treatment to air, wastewater and waste.

Do not add wastewater to a biological wastewater treatment plant

Bring wastewater containing AOX for professional disposal.

Disposal according to local authority regulations.

Uncleaned packaging

Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.

Waste Key Number

The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.