Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: No information available.
Emergency measure - Eyes: Flush with water for at least 15 minutes.
Emergency measure - Skin: Remove product by wiping, followed by washing with soap and
water.
Emergency measure - Ingestion: Consult a physician.

Fire-fighting measures

Recommended extinguishing agent: Dry chemical, foam and CO2

Product arising from burning: COx, NOx and H2O

Product determined by test: N

Protective equipment: Wear self contained breathing apparatus with full face
piece.

Water stream may spread fire, use spray only to cool
containers exposed to fire.

Accidental release measures

Emergency measures in case of spillage: Sweep and shovel up spilled bulk material. Traces may be
removed by repeated washing with a solvent.

Dispose of by appropriate methods.

Handling and storage

Handling: Wash contaminated containers before using.

minimize skin contact and wash hands before eating and
smoking.

Storage: Store in closed container away from heat, sparks and
combustable material.

Store in a cool, dry place away from fire source.

Packaging of the substance and or preparation: Steel drum (180 kg) or steel pail (18 or 16 kg).

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No information available.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None.

Chemical reaction with water: None.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: 611: Recovery by mechanical collection.

Industry - Possibility of neutralisation: None.

Industry - Possibility of destruction: controlled discharge: No information available.

Industry - Possibility of destruction - incineration: 663: Incinerate, high temperature - long burn(*) with flue

gas scrubbing.


(*): minimum temperature of 1200°C, at least 2 seconds

residence time, excess oxygen.

Industry - Possibility of destruction - water purification: No information available.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: 611: Recovery by mechanical collection.

Public at large - Possibility of neutralisation: None.

Public at large - Possibility of destruction: controlled discharge: No information available.

Public at large - Possibility of destruction - incineration: 663: Incinerate, high temperature - long burn(*) with flue

gas scrubbing.


(*): minimum temperature of 1200°C, at least 2 seconds

residence time, excess oxygen.

Public at large - Possibility of destruction - water purification: No information available.

Public at large - Possibility of destruction - others: None.