Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove person to fresh air if adverse effects are observed.
Emergency measure - Eyes: Rinse with water for at least 15 minutes.

Seek medical attention if irritation develops or persists.
Emergency measure - Skin: Wash with soap and water. Seek medical attention if
irritation develops or persists.
Emergency measure - Ingestion: Do not induce vomiting. Give two glasses of water if the
person is conscious. Seek medical attention immediately,
symptomatic treatment.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, dry chemical and alcohol foam are suitable
extinguishing agents. Water may cause splattering of the
substance but it may be used to cool and protect exposed
material.

Product arising from burning: Combustion products may contain carbon, nitrogen and sulfur
oxides. Smoke, aldehydes and other products may also be
formed.

Product determined by test: N

Protective equipment: Wear a self-contained breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: Wear personal protective equipment cf 2.3.1.

Ventilate the area if spillage is in a confined space or
poorly ventilated area. Prevent entry into sewers or
waterways. Absorb using inert material or collect for
disposal by incineration.

Handling and storage

Handling: Use with adequate ventilation. Wear safety glasses, nitrile
or neoprene gloves and a long sleeve shirt. Launder
contaminated clothing before reuse. Under normal use
conditions, a respirator is not usually required.

Storage: No special precautions.

Keep containers closed when not in use. Ensure storage area
is well ventilated.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery of the substance for reuse is not feasible.

Industry - Possibility of neutralisation: No method of chemical neutralisation of the hazardous
properties is known.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: The substance may be disposed of by incineration at an
approved facility equipped with waste gas treatment to
remove nitrogen and sulfur oxides. (C661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: The substance itself will not enter the public domain.
Recovery from preparations is not feasible. However, the oil
base may be recovered for reuse.

Public at large - Possibility of neutralisation: Not applicable at the concentrations involved.

Public at large - Possibility of destruction: controlled discharge: Not recommended.

Public at large - Possibility of destruction - incineration: Preparations containing the substance may be disposed of by
incineration at an approved facility equipped with waste gas
treatment to remove nitrogen and sulfur oxides. (C661)

Public at large - Possibility of destruction - water purification: Not recommended, the substance must not enter watercourses.

Public at large - Possibility of destruction - others: Preparations used are oil based. The oil should be recovered
for reuse by disposal at an approved waste-oil facility.