Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
Description: Colorless to yellow liquid
Key result
Flash point:
> 125 °C
Atm. press.:
1 013.25 hPa
Interpretation of results:
GHS criteria not met

Description of key information

The flash point of the test substance is >125°C.

Key value for chemical safety assessment

Additional information