Registration Dossier

Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
other: All information in this endpoint has been provided by the ECHA using the 12 year rule, this is data is not owned by the registrant. The reliability is estimated to be at level 2 at a minimum.
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
All information in this endpoint has been provided by the ECHA using the 12 year rule, this is data is not owned by the registrant. The reliability is estimated to be at level 2 at a minimum. Therefore the reliability statement below can be used: Study conducted in accordance with generally accepted scientific principles, possibly with incomplete reporting or methodological deficiencies, which do not affect the quality of relevant results.

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Deviations:
not specified
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
This information not provided in the migrated SNIF dossier (SNIF # 001-3.0.10-01) provided by ECHA

Study design

Contact with:
other: This information not provided in the migrated SNIF dossier (SNIF # 001-3.0.10-01) provided by ECHA

Results and discussion

Test results (Oxidising solids)open allclose all
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
2.4 other: mm/s (migrated information)
Remarks on result:
other: Considering the structure of the molecule and results obtained with similar products, this should be considered as a false positive.
Sample tested:
reference mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
2.2 other: mm/s (migrated information)
Remarks on result:
other: Considering the structure of the molecule and results obtained with similar products, this should be considered as a false positive.

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
Considering the structure of the molecule and results obtained with similar products, this should be considered as a false positive.
Executive summary:

All information in this endpoint has been provided by the ECHA using the 12 year rule, this is data is not owned by the registrant.

Oxidising properties determined by using Annex V - Method A15

Considering the structure of the molecule and results obtained with similar products, this should be considered as a false positive.